Cervical vestibular evoked myogenic potentials (cVEMPs) in patients with superior canal dehiscence syndrome (SCDS).

Roditi Rachel E, Eppsteiner Robert W, Sauter Todd B, Lee Daniel J

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine the usefulness of both amplitude and threshold data from tone-burst cervical vestibular evoked myogenic potential (cVEMP) testing for the evaluation of superior canal dehiscence syndrome (SCDS).

STUDY

DESIGN

Case series with chart review.

SUBJECTS AND

METHODS

Sixty-seven patients underwent cVEMP testing. We correlated mean tone burst cVEMP amplitude and threshold data with temporal bone CT findings. Patients were excluded for Ménière's disease, middle ear disease, or otologic surgery.

RESULTS

Superior canal dehiscence patients had higher mean cVEMP amplitudes (SCDS 173.8 microV vs non-SCDS 69.7 microV, P=0.031) and lower mean thresholds (SCDS 72.8 dB nHL vs non-SCDS 80.9 dB nHL) at 500 Hz.

CONCLUSION

Patients with SCDS have larger amplitudes and lower thresholds on cVEMP testing at 500 Hz. This study supports the utility of tone burst cVEMPs for the evaluation of SCDS and is one of few large single-center studies to establish normative data.

Для цитирования: Roditi Rachel E, Eppsteiner Robert W, Sauter Todd B, Lee Daniel J. Cervical vestibular evoked myogenic potentials (cVEMPs) in patients with superior canal dehiscence syndrome (SCDS).. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2009. DOI: 10.1016/j.otohns.2009.03.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.