MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of reproductive medicine · 2001

Microwave endometrial ablation at a frequency of 2.45 GHz. A pilot study.

Kanaoka Y, Hirai K, Ishiko O, Ogita S

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate the clinical application of a microwave tissue coagulator at 2.45 GHz with a needle electrode customized for endometrial ablation.

STUDY

DESIGN

In a pilot clinical study, endometrial ablation was performed under intravenous thiopental anesthesia on five women suffering from hypermenorrhea caused by aplastic anemia (3), von Willebrand's disease (1) and a submucosal myoma (1) using a microwave tissue coagulator at 2.45 GHz.

RESULTS

Four patients were amenorrheic after endometrial ablation. The patient with the submucosal myoma experienced minor menstrual bleeding. No notable complications were observed during or after ablation.

CONCLUSION

Endometrial ablation using a microwave tissue coagulator at 2.45 GHz is a simple and useful method of treating hypermenorrhea.

Для цитирования: Kanaoka Y, Hirai K, Ishiko O, Ogita S. Microwave endometrial ablation at a frequency of 2.45 GHz. A pilot study.. The Journal of reproductive medicine. 2001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.