MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15209156261496643

Медицинская библиотека · Diabetes technology & therapeutics · 2026

Roadmap to Fully Closing the Loop to Optimize Health in Type 1 Diabetes.

Marks Brynn E, Hilliard Marisa E, Kovatchev Boris, Moser Othmar, Tanenbaum Molly L, Ackeifi Courtney, Ahn David T, Ajjan Ramzi A, Albanese-O'Neill Anastasia, Bakhsh Abdulmohsen, Choudhary Pratik, Close Kelly L, Davis Elizabeth A, Dovc Klemen, Dutta Sanjoy, Garg Satish, Forlenza Gregory P, Heverly Julie, Kowalski Aaron J, Limbert Catarina, Maahs David M, Mader Julia K, Marinac Marjana, Mathieu Chantal, Nimri Revital, Nishimura Rimei, O'Neal David N, Oxenreiter Monica, Press Chengyuan, Rickels Michael R, Riddell Michael C, Rosen Jonathan, Saboo Banshi, Shah Viral N, Sherr Jennifer L, Wheeler Benjamin J, Phillip Moshe, Battelino Tadej, Danne Thomas

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Current commercially available automated insulin delivery systems require meal and exercise announcements for optimal function, placing them in the hybrid closed loop category. Ongoing advancements aim to establish fully closed loop (FCL) systems as the next-generation standard for type 1 diabetes (T1D) management, eliminating the need for such inputs. We sought to develop a shared definition of FCL so that emerging technologies, including those using artificial intelligence, multi-hormone delivery, multi-analyte sensing, and/or adjunctive therapies, are held to uniform performance standards.

METHODS

A group of invited experts, including clinicians, researchers, and people with lived experience convened to propose an outcome-driven definition of FCL systems.

RESULTS

FCL systems are defined by three core domains centered on meeting intensive glycemic targets while reducing self-management burden and improving lived experience: Time in Tight Range (TITR) 70-140 mg/dL (3.9-7.8 mmol/L), Time Below Range (TBR) <54 mg/dL (<3.0 mmol/L), and person-reported outcomes (PROs) measured with validated T1D-specific assessments. This definition rests on a three-tiered classification in which all FCL systems improve lived experience and attain >50% TITR and <1% TBR without mandatory meal or activity announcements. Class 3 systems must attain >50% TITR; Class 2, >70%; and Class 1, >90%-while simultaneously demonstrating improved quality of life and reduced treatment burden per validated PROs. Given the elevated hypoglycemia risk from insulin-on-board during exercise, Class 1a requires >90% TITR with demonstrable hypoglycemia prevention during standardized exercise testing (0% TBR).

CONCLUSION

This framework provides a uniform benchmark for evaluating future FCL technologies. Taken together, this person-centered, outcome-driven framework holds that FCL systems should (1) autonomously attain near-normoglycemia, (2) meaningfully improve lived experience across the lifespan and clinical contexts, and (3) prevent exercise-related hypoglycemia.

Для цитирования: Marks Brynn E, Hilliard Marisa E, Kovatchev Boris, Moser Othmar, Tanenbaum Molly L, Ackeifi Courtney, Ahn David T, Ajjan Ramzi A, Albanese-O'Neill Anastasia, Bakhsh Abdulmohsen, Choudhary Pratik, Close Kelly L, Davis Elizabeth A, Dovc Klemen, Dutta Sanjoy, Garg Satish, Forlenza Gregory P, Heverly Julie, Kowalski Aaron J, Limbert Catarina, Maahs David M, Mader Julia K, Marinac Marjana, Mathieu Chantal, Nimri Revital, Nishimura Rimei, O'Neal David N, Oxenreiter Monica, Press Chengyuan, Rickels Michael R, Riddell Michael C, Rosen Jonathan, Saboo Banshi, Shah Viral N, Sherr Jennifer L, Wheeler Benjamin J, Phillip Moshe, Battelino Tadej, Danne Thomas. Roadmap to Fully Closing the Loop to Optimize Health in Type 1 Diabetes.. Diabetes technology & therapeutics. 2026. DOI: 10.1177/15209156261496643.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.