Atrial Flow Regulator for Left Atrial Hypertension-Mediated Recurrent Heart Failure Post-Mitral Transcatheter Edge-to-Edge Repair.

Sooknanan Naveen N, Fernandez-Hazim Carol M, Tuluca Alexandra, Pressman Gregg, Witzke Christian, Copeland Joshua A

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Impaired left atrial (LA) compliance can trigger dynamic left atrial hypertension (LAH), resulting in recurrent pulmonary edema. LAH after mitral transcatheter edge-to-edge repair (M-TEER) can cause particularly unfavorable hemodynamics.

CASE SUMMARY: A 70-year-old woman developed recurrent pulmonary edema after emergent M-TEER for severe functional mitral regurgitation (MR). Echocardiography revealed only mild residual MR with severe left atrial (LA) enlargement and reduced reservoir strain. Invasive hemodynamics showed increased LA pressure with tall V-waves, suggestive of dynamic LAH because of reduced LA compliance. Balloon atrial septostomy initially improved symptoms and hemodynamics, but heart failure recurred. An atrial flow regulator (AFR) was implanted under compassionate use, producing durable left-to-right shunting with no further heart failure hospitalizations at 12 months.

DISCUSSION: To our knowledge, this is the first reported use of an AFR in LAH post-M-TEER, demonstrating its potential role in these patients.

TAKE-HOME MESSAGES: In patients with unexplained recurrent pulmonary edema after successful M-TEER, tall LA V-wave pressure tracings in the absence of significant residual MR can suggest reduced LA compliance and LAH. AFR implantation may offer durable LA decompression in carefully selected cases.

Для цитирования: Sooknanan Naveen N, Fernandez-Hazim Carol M, Tuluca Alexandra, Pressman Gregg, Witzke Christian, Copeland Joshua A. Atrial Flow Regulator for Left Atrial Hypertension-Mediated Recurrent Heart Failure Post-Mitral Transcatheter Edge-to-Edge Repair.. JACC. Case reports. 2026. DOI: 10.1016/j.jaccas.2026.110447.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.