MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2026.119161

Медицинская библиотека · Biosensors & bioelectronics · 2026

Controlled microfluidic tank integrated AgNPs-coated paper-based impedimetric immunosensor for leukemia biomarker detection and complete validation through 3i-study in-silico, in-vitro, in-vivo.

Rizwan Amber, Hasan Mohd Rahil, Khan Sameer, Kumari Swati, Choudhary Furqan, Ali Mohd Mohsin, Narang Jagriti, Farooqi Humaira

СтатьяПеревод пока не подготовлен

Аннотация

Leukemia, a critical hematological malignancy, demands early and accurate diagnosis to improve outcomes. In present work a 3D-printed microfluidic platform enables sensitive, label-free PHB2 detection via an AgNP-based paper immunosensor. Silver nanoparticles enhance electron transfer kinetics and provide a high surface area for efficient antibody immobilization, improving sensor performance. Electrochemical impedance spectroscopy (EIS) measurements show a stepwise increase in charge-transfer resistance (Rct) upon antigen-antibody interaction, confirming the sensing mechanism. The immunosensor exhibits a linear detection range of 2.5-40 ng mL-1 with a limit of detection of 2.5 ng mL-1. The platform demonstrates high selectivity against interfering biomarkers, excellent reproducibility, satisfactory recovery in spiked samples, and stable performance for up to 15 days. Biological validation using serum samples (animal serum and synthetic serum), HL-60 cell lines, and a BALB/c mouse model confirms its applicability in complex matrices. In silico and in vitro studies further support PHB2 as a diagnostic target. The platform offers a sensitive, portable, and cost-effective approach for point-of-care leukemia screening.

Для цитирования: Rizwan Amber, Hasan Mohd Rahil, Khan Sameer, Kumari Swati, Choudhary Furqan, Ali Mohd Mohsin, Narang Jagriti, Farooqi Humaira. Controlled microfluidic tank integrated AgNPs-coated paper-based impedimetric immunosensor for leukemia biomarker detection and complete validation through 3i-study in-silico, in-vitro, in-vivo.. Biosensors & bioelectronics. 2026. DOI: 10.1016/j.bios.2026.119161.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.