m+Medelevator.RU
← Поиск публикаций
Journal of veterinary internal medicine · 2026

Validation of a point-of-care assay for simultaneous quantification of equine adrenocorticotropic hormone and corticotropin-like intermediate peptide.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hart Kelsey A, Berghaus Londa J, Harmon Ian

Аннотация

BACKGROUND: Plasma adrenocorticotropic hormone (ACTH) concentrations are used to diagnose equine pituitary pars intermedia dysfunction (PPID). The reference chemiluminescent immunoassay for immunoreactive ACTH (iACTH) cross-reacts with corticotropin-like intermediate peptide (CLIP), which is also abnormally high in PPID.

HYPOTHESIS/OBJECTIVES: To compare the performance of a novel point-of-care (POC) immunoassay that concurrently measures ACTH and CLIP against the reference iACTH assay.

ANIMALS: Twenty-eight university-owned horses (13 PPID, 15 non-PPID).

METHODS: Prospective observational study. Resting plasma hormone concentrations in all animals were measured by both methods in all seasons over 1 year, and after thyrotropin releasing hormone (TRH)-stimulation testing once. Bias of the POC-ACTH/CLIP assay was assessed using Spearman correlation analysis and Bland-Altman plots, and precision and linearity of the POC-ACTH/CLIP assay were determined.

RESULTS: For resting and TRH-stimulated ACTH concentrations, the POC-ACTH/CLIP assay and the reference method had good agreement overall (r ≥ 0.94; P < .001) and in PPID animals (r = 0.93, P < .001). Bias was greater in autumn (33.6-35.6 ± 89.5-96 pg/mL) compared to winter/spring (1.6-11.1 ± 8.4-29.6 pg/mL) and in samples with ACTH concentrations ≥ 90 pg/mL (87.8 ± 116.4 pg/mL). Intra- and inter-assay coefficients of variation for the POC-ACTH/CLIP assay were 8.47% and 14.1%, respectively, and assay linearity was excellent (R2 = 0.991).

CONCLUSIONS AND CLINICAL IMPORTANCE: These data demonstrate acceptable field performance for the POC-ACTH/CLIP assay and good agreement with the chemiluminescent iACTH immunoassay, with a larger bias in samples with higher hormone concentrations.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты