m+Medelevator.RU
← Поиск публикаций
ArXiv · 2026

Quantifying the Impact of Upright Patient Positioning on Cardiac Substructures Using Deep Learning.

СтатьяПрепринтНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Summerfield Nicholas, Yan Yuhao, Ruff Chase, Pankuch Mark, Gans Shae, Schreuder Niek, Glide-Hurst Carri K

Аннотация

Upright patient positioners with diagnostic-quality vertical CT at treatment isocenter may improve image-guided radiation therapy (RT). However, cardiac substructure (CS) geometry in upright patients remains insufficiently characterized. This work evaluated if a supine-trained deep-learning (DL) CS segmentation model generalizes to upright CT images and quantified posture-dependent CS changes in thoracic patients, to assess potential CS-sparing benefits. 8 thoracic proton therapy patients underwent paired supine/upright 4DCT imaging. 20 CS and lungs were manually labeled on both datasets for positional comparisons. A previously developed supine-trained, DL pipeline generated the same CS, and performance was evaluated using Dice similarity coefficient (DSC) and 95% Hausdorff distance (HD95). Upright CTs were rigidly registered to corresponding supine CTs by aligning the thoracic vertebrae, and CS centroid shifts were measured in the registered coordinate frame and relative to the carina. Paired differences were assessed using Wilcoxon signed-rank tests (p<0.05). The DL model successfully predicted all 20 CS on both upright (DSC, 0.65(0.24); HD95, 7.6(5.6)mm) and supine (DSC, 0.72(0.19); HD95, 5.8(2.6)mm) images yet with lower (p<0.05) performance upright. Upright positioning significantly increased median lung volume by 20.6% (range, -8.9%-42.8%). After vertebral alignment, most CS centroids shifted significantly inferior (median heart shift, 23mm; range, 18-37mm) and anterior (median heart shift, 5.0mm; range, 1.0-13.0mm) when upright. Relative to the carina, most CS shifted significantly inferior and closer anterior-posterior. A supine-trained DL model generalized to upright CT images for CS segmentation. Upright positioning produced increased lung volumes and significant inferior CS displacement, suggesting favorable geometry changes that may support cardiac-sparing workflows.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты