INTRODUCTION

We report unique and rare findings of coupled electrical and mechanical alternans in a patient with extreme QT prolongation.

METHODS

A 5-year-old girl with congenital long QT syndrome type 3 developed alternate left ventricular apical ballooning precipitated by mycoplasma pneumonia and azithromycin exposure.

RESULTS

During atrial pacing, electrocardiography showed beat-to-beat alternation not only in T-wave morphology but also in QRS configuration, ST segment, and QT interval. These electrical changes were tightly associated with mechanical alternans: beats with markedly prolonged QT intervals showed normal left ventricular (LV) contraction, whereas beats with shorter QT intervals and ST elevation exhibited LV apical ballooning. Treatment with mexiletine shortened the QT interval, abolished both electrical and mechanical alternans, and restored normal LV function.

CONCLUSIONS

Alternate LV apical ballooning mimicking Takosubo cardiomyopathy can be seen in a patient with extreme QT prolongation. These findings probably reflected a functional intraventricular conduction block due to marked spatial heterogeneity of repolarization between the LV base and apex.

Для цитирования: Saprungruang Ankavipar, Lekchuensakul Sarin, Kanjanauthai Supaluck, Khongphatthanayothin Apichai. Electrical Alternans With Alternating Left Ventricular Apical Ballooning Mimicking Takotsubo Cardiomyopathy in a Patient With Extreme QT Prolongation.. Journal of cardiovascular electrophysiology. 2026. DOI: 10.1111/jce.70501.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.