MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fbioe.2026.1937182

Медицинская библиотека · Frontiers in bioengineering and biotechnology · 2026

Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis.

Yoo Sun-Joon, Moon Bong-Ju, Eom Jung-Do, Won Young-Hoon, Oh Jae Keun, Kim Kyung-Hyun

СтатьяПеревод пока не подготовлен

Аннотация

Proximal junctional complications are often driven by abrupt mechanical transition at the uppermost instrumented vertebra (UIV). This study used patient-specific finite element analysis to compare biomechanical effects of transverse process hooks and pedicle screws at the UIV, specifically examining how hook orientation influences anterior-posterior load sharing. A validated nonlinear three-dimensional T7-L2 spinal model was developed using data from a 60-year-old woman. Three UIV constructs were evaluated at T9: bilateral pedicle screws (BPS) and downward and upward facing transverse process hook (TPH) configurations. Under a 500-N follower load and 8-Nm bending moments, we analyzed facet joint load (FJL), range of motion (ROM), intradiscal pressure, and mechanical failure risk. In flexion, FJL at the UIV+1/UIV level decreased by 6.2% and 19.6% in the downward-facing and upward-facing TPH models, respectively, compared with the BPS model. In extension, FJL decreased by 4.2% in the upward-facing TPH model, but increased by 32.4% in the downward-facing TPH model, relative to the BPS model. Both TPH models preserved greater UIV ROM than the bilateral pedicle screw model, with the upward-facing configuration achieving the highest flexion ROM (2.1°) and the downward-facing configuration achieving the highest extension ROM (3.2°). In the BPS model, UIV screw pull-out risk was 136% in flexion. Conversely, the risks of transverse process breakage for the downward-facing and upward-facing TPH models were substantially lower (50% and 42%, respectively). Hook constructs increased screw pull-out risk at the UIV-1 level compared with the BPS model. Using the TPH at the UIV can facilitate a biomechanical "soft landing" by preserving segmental motion and reducing posterior load at adjacent levels. These effects are orientation-dependent, with the upward-facing TPH configuration potentially offering greater advantage in preserving segmental motion during flexion. Surgical strategies should be tailored to individual bone quality due to potential stress transfer to the UIV-1 level.

Для цитирования: Yoo Sun-Joon, Moon Bong-Ju, Eom Jung-Do, Won Young-Hoon, Oh Jae Keun, Kim Kyung-Hyun. Direction-dependent biomechanical effects of transverse process hooks versus pedicle screws at the uppermost instrumented vertebra in adult spinal deformity: a finite element analysis.. Frontiers in bioengineering and biotechnology. 2026. DOI: 10.3389/fbioe.2026.1937182.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.