m+Medelevator.RU
← Поиск публикаций
Medical physics · 2026

Simultaneous T1, T2, R2*, PDFF, and triglyceride quantification in the head and neck using magnetic resonance fingerprinting on a 1.5T MR-Linac.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

McCullum Lucas, Subashi Ergys, Mulder Samuel L, Taylor Brian A, Hwang Ken-Pin, Fuller Clifton D, Ostenson Jason

Аннотация

BACKGROUND: The extraction of quantitative biomarkers on the MR-Linac, which have been shown to be promising in the head and neck, remains a significant challenge due to the strict time constraints.

PURPOSE: The purpose of this study was to assess the technical feasibility of magnetic resonance fingerprinting (MRF) to simultaneously extract quantitative T1, T2, R2*, PDFF, and triglyceride composition in the head and neck on the MR-Linac.

METHODS: Inversion-prepared, multi-echo, golden angle radial, variable flip angle, MRF data were acquired on a 1.5T MR-Linac. The data were corrected for phase errors in the bipolar multi-echo acquisition followed by low rank reconstruction with total variation regularization. A dictionary of signals parameterized by T1/T2 was calculated with an extended phase graph algorithm. The singular images were constructed using a signal subspace from the dictionary and the first singular images were then jointly fit for R2* and PDFF using the off-resonance information from an independent B0 map. The complete set of B0/T2*-corrected fat-water separated water singular images were fitted for T1/T2. Triglyceride composition was computed using the multi-echo complex readout. Three phantoms and three healthy volunteers were assessed for accuracy, repeatability, and reproducibility against validated reference sequences across five days using a test-retest setup.

RESULTS: All coefficients of determination were at least 0.9 against reference sequences in standard phantoms across all quantitative parameters. The repeatability and reproducibility averaged under 5% in phantoms and under 10% in healthy volunteers.

CONCLUSION: The proposed MRF acquisition demonstrated the potential to replace the current time-intensive sequences on the 1.5T MR-Linac, thus increasing the adoption of specialized quantitative imaging biomarker approaches at high temporal density in the head and neck.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты