MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apradiso.2026.112986

Медицинская библиотека · Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026

Dosimetry validation via EGS5 Monte Carlo simulation, microbial inactivation kinetics, and quality preservation of frozen sliced squid (Loligo spp.) under 10 MeV electron beam irradiation.

Hoang Sy Minh Tuan

СтатьяПеревод пока не подготовлен

Аннотация

High-energy (10 MeV) electron beam (e-beam) irradiation was investigated as a non-thermal intervention for vacuum-packaged frozen sliced squid (Loligo spp.). Absorbed doses ranged from 1 to 5 kGy, with storage at -18 °C for eight weeks. A core challenge was dosimetry mapping within deep-frozen bulk geometries, since standard B3 thin-film dosimeters lose chemical validity below their glass transition temperature. This was addressed using the Electron Gamma Shower version 5 (EGS5) Monte Carlo code. A dual-beam configuration achieved a Dose Uniformity Ratio (DUR) of 1.18, confirmed via B3 dosimetry in a density-matched phantom, with agreement within 1.7%. Sensitivity analysis showed a 10% fluctuation in phantom density did not raise the DUR beyond 1.28, confirming robustness against packaging variation. Using a high-bioburden challenge model with an initial Total Viable Count (TVC) of 6.8 log CFU/g, the 2 kGy treatment reduced TVC to 2.6 log CFU/g, a 4.2-log reduction, remaining below the 6.0 log CFU/g threshold throughout storage. Lipid oxidation, tracked via Peroxide Value (PV) and Thiobarbituric Acid Reactive Substances (TBARS), followed zero-order kinetics; the 2 kGy treatment yielded a final TBARS concentration of 0.68 mg MDA/kg, below the 1.0 mg MDA/kg sensory rejection threshold. Total color difference (ΔE*) and Warner-Bratzler shear force changes remained within commercially acceptable limits. A discriminative Triangle Test (ISO 4120:2021) detected no statistically significant organoleptic difference, though post-hoc power analysis indicated limited power for strict equivalence. These results support 2 kGy dual-beam e-beam processing as a technologically sound, quantitatively validated intervention for frozen cephalopod safety and quality assurance.

Для цитирования: Hoang Sy Minh Tuan. Dosimetry validation via EGS5 Monte Carlo simulation, microbial inactivation kinetics, and quality preservation of frozen sliced squid (Loligo spp.) under 10 MeV electron beam irradiation.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 2026. DOI: 10.1016/j.apradiso.2026.112986.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.