A needle in a haystack: Endoscopic removal of a foreign body from the infratemporal fossa.
Аннотация
BACKGROUND
This report presented the case of a difficult-to-remove needle foreign body. The patient had a dental procedure in which a 30-gauge needle was lost in the gingival buccal sulcus. Several attempts at removal were unsuccessful. The patient presented to the otolaryngology clinic with trismus, pain with mastication, intermittent right otalgia, and numbness of the right cheek.
METHODS
The needle was finally localized in the infratemporal fossa and removed by using image guidance technology.
RESULTS
This case demonstrated an approach to a difficult-to-locate foreign body removal and the importance of intraoperative imaging in foreign body localization.
CONCLUSION
Foreign bodies of the infratemporal fossa and posterior orbit are better removed via endoscopic than open technique.