MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2026.09.050

Медицинская библиотека · Academic radiology · 2026

Implementation of a Structured Peer Learning Program and Missed Critical Findings in a Large Integrated Radiology Practice: A Baseline Retrospective Analysis.

Ballenger Zachary, Ward Thomas J, Theadore Jason C, Koury Ibrahim F, Bhimani Asif, Taylor RoyLynn, Loriga Vanessa, Segarra Aramis, Gonzalez Felix M

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

The American College of Radiology (ACR) defines peer learning as nonpunitive, education-centered case review, separated from individual performance evaluation. We describe a program designed against ACR criteria in a large integrated practice and report first-cycle metrics, including missed critical findings-a narrow subset of major misses.

MATERIALS AND

METHODS

This retrospective analysis spanned 283 radiologists across more than 100 sites between March 30 and May 14, 2026. Cases entered through voluntary worklist submission, risk-event referral, and departmental escalation, and were adjudicated by a fellowship-trained coordinator. A missed critical finding (MCF) required both a finding on the institutional critical results list (provider notification within 30 minutes) and a 4B classification, with agreement between two independent reviewers. Exact (Poisson) 95% confidence intervals (CI) were calculated.

RESULTS

Of 702 submissions, 489 (69.7%) were Learning Opportunities, 187 (26.6%) Great Calls, and 26 (3.7%) Agrees. Of 283 radiologists, 182 (64.3%) submitted at least one case, and 213 (75.3%) received feedback; two conferences were held. Of 17 candidates, reviewers concurred on 7 at initial review; the 10 discordant were resolved by consensus, none meeting criteria. Across 409,122 interpreted studies, the confirmed MCF rate was 0.017 per 1000 (95% CI 0.007-0.035). Seven radiologists (2.5%) had one event; none had more. No confirmed event had been independently filed as a safety event.

CONCLUSION

The MCF rate reflects a narrow, time-critical subset ascertained with unmeasured sensitivity against a diluted denominator. It is a conservative internal baseline, not a measure of diagnostic accuracy or individual performance.

Для цитирования: Ballenger Zachary, Ward Thomas J, Theadore Jason C, Koury Ibrahim F, Bhimani Asif, Taylor RoyLynn, Loriga Vanessa, Segarra Aramis, Gonzalez Felix M. Implementation of a Structured Peer Learning Program and Missed Critical Findings in a Large Integrated Radiology Practice: A Baseline Retrospective Analysis.. Academic radiology. 2026. DOI: 10.1016/j.acra.2026.09.050.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.