MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13244-026-02397-z

Медицинская библиотека · Insights into imaging · 2026

Reproducibility and diagnostic performance of ADC for assessing response to neoadjuvant immunotherapy in muscle-invasive bladder cancer: a multi-ROI comparison analysis from the phase-Ib NABUCCO trial.

Greidanus Joyce, Bernabei Carlotta, Chupetvloska Kalina, Agrotis Georgios, Mertens Laura S, van Rhijn Bas W G, van der Poel Henk G, van der Heijden Michiel S, Beets-Tan Regina G H, Pizzi Andrea Delli, Boellaard Thierry N, Trebeschi Stefano

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

MRI is increasingly used to assess treatment response in muscle-invasive bladder cancer (MIBC), but only qualitatively. This study evaluates the reproducibility and predictive value of quantitative apparent diffusion coefficient (ADC), thought to be a non-invasive surrogate for tumor cell density, in patients with MIBC receiving neoadjuvant immunotherapy.

MATERIALS AND

METHODS

MRI data from 35 patients, enrolled in the Phase-Ib NABUCCO trial, were analyzed. ADC maps were derived from pre- and post-treatment MRI scans. Three independent radiologists assessed multiple regions of interest (ROIs) to evaluate inter-observer agreement and predictive performance for pathological complete response (pCR). ADC values were normalized using muscle tissue as a reference. Additionally, we analyzed the correlation between ADC and cell densities, derived from multiplex immunofluorescence (mIF) data.

RESULTS

ADC measurements from the whole-tumor ROI (n = 25) demonstrated the highest reproducibility (0.98, 95% CI = [0.95-0.99]), but lacked predictive value (AUC = 0.31, 95% CI = [0.12-0.53], p = 0.109). The most hypointense ROI (n = 22) showed the strongest predictive value for pCR (AUC = 0.80, 95% CI = [0.57-1], p = 0.025), though with limited reproducibility. The difference between baseline and follow-up ADC values in the hypointense region (n = 20) again showed the highest diagnostic accuracy (AUC = 0.80, 95% CI = [0.58-0.98], p = 0.015). Although muscle normalization is proposed to reduce scanner variability, it did not improve predictive performance in this cohort and occasionally reduced reproducibility. No significant correlation was found between whole-tumor ADC and cell density.

CONCLUSION

Despite analyzing different measurement techniques for ADC values, none was simultaneously reproducible and predictive, nor provided insights into the biology of the tumor. While ADC shows promise in MIBC, there is an urgent need for more standardized, robust imaging biomarkers.

KEY POINTS: Question Non-invasive biomarkers are urgently needed to guide bladder-preserving strategies in MIBC. Findings DWI-MRI shows promise, but standardized robust imaging biomarkers are essential for reliable response assessment. Critical relevance statement Standardized or AI-assisted ROI segmentation could improve ADC reproducibility and diagnostic accuracy in multicenter studies.

Для цитирования: Greidanus Joyce, Bernabei Carlotta, Chupetvloska Kalina, Agrotis Georgios, Mertens Laura S, van Rhijn Bas W G, van der Poel Henk G, van der Heijden Michiel S, Beets-Tan Regina G H, Pizzi Andrea Delli, Boellaard Thierry N, Trebeschi Stefano. Reproducibility and diagnostic performance of ADC for assessing response to neoadjuvant immunotherapy in muscle-invasive bladder cancer: a multi-ROI comparison analysis from the phase-Ib NABUCCO trial.. Insights into imaging. 2026. DOI: 10.1186/s13244-026-02397-z.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.