Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
Impact of Hemoglobin Levels on Therapeutic Efficacy and Energy Dosage in Ultrasound-Guided HIFU Ablation of Uterine Fibroids.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yang Meijie, Qiu Yaxuan, Hu Liang, Zhou Xue, Yu Renqiang, Chen Jinyun
Аннотация
OBJECTIVES: To investigate the impact of hemoglobin (HGB) levels on therapeutic efficacy and energy dosage during ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation of symptomatic uterine fibroids (UFs).
METHODS: A total of 1196 patients who underwent USgHIFU for symptomatic UFs were retrospectively enrolled. Patients were stratified into 8 subgroups based on preprocedural HGB concentrations (g/L): <60, 60-70, 70-80, 80-90, 90-100, 100-110, 110-120, and >120. The energy efficiency factor (EEF) was used to quantify the ablation dose, and non-perfused volume ratio (NPVR) was adopted to evaluate ablation efficacy.
RESULTS: The overall median EEF was 3.96 J/mm3. EEF was significantly lower in the <60 (3.63 J/mm3) and 60-70 g/L (4.75 J/mm3) groups than in the 80-90 g/L group (6.62 J/mm3), and the 80-90 g/L group had higher EEF than the >120 g/L group. The proportion of T2-weighted imaging hyperintense fibroids (Funaki type 3) and NPVR was both higher in the 80-90 g/L group than in the >120 g/L group.
CONCLUSION: Lower preprocedural HGB levels correlate with higher NPVR. During moderate anemia, EEF increases with rising HGB, which may serve as useful reference evidence for individualized energy dose adjustment in clinical practice.
METHODS: A total of 1196 patients who underwent USgHIFU for symptomatic UFs were retrospectively enrolled. Patients were stratified into 8 subgroups based on preprocedural HGB concentrations (g/L): <60, 60-70, 70-80, 80-90, 90-100, 100-110, 110-120, and >120. The energy efficiency factor (EEF) was used to quantify the ablation dose, and non-perfused volume ratio (NPVR) was adopted to evaluate ablation efficacy.
RESULTS: The overall median EEF was 3.96 J/mm3. EEF was significantly lower in the <60 (3.63 J/mm3) and 60-70 g/L (4.75 J/mm3) groups than in the 80-90 g/L group (6.62 J/mm3), and the 80-90 g/L group had higher EEF than the >120 g/L group. The proportion of T2-weighted imaging hyperintense fibroids (Funaki type 3) and NPVR was both higher in the 80-90 g/L group than in the >120 g/L group.
CONCLUSION: Lower preprocedural HGB levels correlate with higher NPVR. During moderate anemia, EEF increases with rising HGB, which may serve as useful reference evidence for individualized energy dose adjustment in clinical practice.