DOI 10.1007/s10840-026-02241-w
Biatrial cardioneuroablation guided by robotic magnetic navigation and artificial intelligence-based mapping in vagal bradyarrhythmias: A controlled observational study.
Аннотация
PURPOSE: Reflex bradyarrhythmias and syncope related to excessive vagal tone may be refractory to conservative therapy and significantly impair quality of life. Cardioneuroablation (CNA) has emerged as a device-sparing alternative, but real-world outcome data remain limited.
METHODS
We retrospectively evaluated 12 consecutive patients (aged 23-55 years) with drug-refractory, vagally mediated bradyarrhythmias confirmed by tilt-table testing. All underwent biatrial CNA guided by ultra-high-density electroanatomical mapping with automated fragmented-electrogram detection and robotic magnetic navigation. A contemporaneous cohort of medically managed patients with comparable clinical profiles (n = 10) served as a control group. The primary outcome was freedom from syncope or clinically significant bradyarrhythmia without pacemaker implantation. Secondary outcomes included procedural metrics, heart-rate changes, and recurrence during follow-up.
RESULTS
All CNA procedures were completed without acute complications and with minimal fluoroscopy exposure. Resting sinus rate increased substantially after ablation. Over a mean follow-up of approximately 12 months, most CNA-treated patients remained free of symptomatic bradyarrhythmia or syncope without requiring pacemaker implantation, whereas recurrence and pacemaker placement were less frequent compared with controls. No delayed complications were observed.
CONCLUSIONS
In this small, retrospective real-world cohort, biatrial CNA guided by automated electrogram analysis and robotic navigation was feasible, safe, and associated with short-term autonomic modulation and symptomatic improvement over approximately 12 months of follow-up in selected patients with vagally mediated bradyarrhythmias. These findings are exploratory and warrant confirmation in larger, prospective studies with longer follow-up to assess durability and reinnervation risk.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.