Screening for Open Spina Bifida in a Routine Clinical Setting at the First-Trimester Scan: A Prospective Multicentre Cohort Study.

Tiechl Johanna, Abdel Azim Samira, Leitner Katharina, Berger Astrid, Mutz-Dehbalaie Irene, Goebel Georg, Scheier Matthias

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of this study was to investigate the performance of screening for open spina bifida (OSB) integrated into the routine first-trimester screening.

METHOD: This is a prospective multicentre study of 4,755 women undergoing first-trimester ultrasound scans over a 4-year period. Measurements of the brainstem (BS) diameter and brainstem-to-occipital-bone (BSOB) distance were performed. The cisterna magna (CM) was measured in the tilted axial view.

RESULTS

Pregnancy outcome data were available for 4,658 fetuses included in this study. There were 5 fetuses with OSB, and in all of them, the BS/BSOB ratio and the CM measurements were abnormal. The sensitivity and specificity of a BS/BSOB ratio >1 were 100%. The sensitivity of a CM width <5th centile was 100%, and the specificity was 95.1%. In 4.6% of cases, the BS/BSOB ratio was between the 95th percentile and 1. In 87.1% of these cases, the CM was normal, and 12.9% had a CM below the 5th percentile.

CONCLUSION

Screening for OSB is feasible in routine first-trimester scans. The BS/BSOB ratio shows a very good sensitivity and specificity. In cases with near-normal values for the BS/BSOB ratio, the CM width might be helpful for further assessment.

Для цитирования: Tiechl Johanna, Abdel Azim Samira, Leitner Katharina, Berger Astrid, Mutz-Dehbalaie Irene, Goebel Georg, Scheier Matthias. Screening for Open Spina Bifida in a Routine Clinical Setting at the First-Trimester Scan: A Prospective Multicentre Cohort Study.. Fetal diagnosis and therapy. 2021. DOI: 10.1159/000512487.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.