Cornea · 2024
Descemet Stripping Endothelial Keratoplasty in Patients With a Custom Foldable Silicone Artificial Iris: Safety and Efficacy Outcomes.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tran Tu M, Bonnet Clemence, Chea Piseth Dalin, Masoudi Ali, Aldave Anthony J, Hardten David R, Miller Kevin M
Аннотация
PURPOSE: To assess outcomes of Descemet stripping endothelial keratoplasty (DSEK) in eyes with custom artificial iris (CAI) implantation.
METHODS: This is a retrospective, interventional, consecutive, surgical case series of patients who underwent DSEK after CAI implantation between 2010 and 2021 at 2 referral centers. Primary safety measures were loss of corrected distance visual acuity (CDVA), increase in intraocular pressure (IOP), development or progression of glaucoma, and intraoperative and postoperative complications. Efficacy measures were graft survival at year 1 and improvement in cosmesis at postoperative month 3. In general, measures were compared between baseline and postoperative year 1 while any complication was reported for the full follow-up period.
RESULTS: Thirty-nine eyes of 39 patients were identified. 64.1% of eyes had acquired aniridia from trauma. The mean follow-up interval was 27.7 months (range 12.2-117.4). Median CDVA improved from logMAR 1.0 to 0.7 at year 1 ( P = 0.0047). At the final follow-up, permanent loss of CDVA occurred in 25.6% of eyes, of which 90% was due to glaucoma. The most common postoperative complication was IOP elevation (66.7% of eyes). Graft survival at postoperative year 1 was 82.0% (95% confidence interval, 66.3-91.4). Secondary graft failure occurred in 28.2% of eyes at a mean duration of 39.7 months (SD 27.9 months) after DSEK. Cosmesis improved among 87.2% of eyes at postoperative month 3.
CONCLUSIONS: DSEK is an effective procedure for addressing corneal edema in eyes with a CAI, but a majority develop elevated IOP and graft survival is shorter than in eyes without a CAI.
METHODS: This is a retrospective, interventional, consecutive, surgical case series of patients who underwent DSEK after CAI implantation between 2010 and 2021 at 2 referral centers. Primary safety measures were loss of corrected distance visual acuity (CDVA), increase in intraocular pressure (IOP), development or progression of glaucoma, and intraoperative and postoperative complications. Efficacy measures were graft survival at year 1 and improvement in cosmesis at postoperative month 3. In general, measures were compared between baseline and postoperative year 1 while any complication was reported for the full follow-up period.
RESULTS: Thirty-nine eyes of 39 patients were identified. 64.1% of eyes had acquired aniridia from trauma. The mean follow-up interval was 27.7 months (range 12.2-117.4). Median CDVA improved from logMAR 1.0 to 0.7 at year 1 ( P = 0.0047). At the final follow-up, permanent loss of CDVA occurred in 25.6% of eyes, of which 90% was due to glaucoma. The most common postoperative complication was IOP elevation (66.7% of eyes). Graft survival at postoperative year 1 was 82.0% (95% confidence interval, 66.3-91.4). Secondary graft failure occurred in 28.2% of eyes at a mean duration of 39.7 months (SD 27.9 months) after DSEK. Cosmesis improved among 87.2% of eyes at postoperative month 3.
CONCLUSIONS: DSEK is an effective procedure for addressing corneal edema in eyes with a CAI, but a majority develop elevated IOP and graft survival is shorter than in eyes without a CAI.
Предметные рубрики MeSH
HumansDescemet Stripping Endothelial KeratoplastyRetrospective StudiesMaleFemaleVisual AcuityMiddle AgedAgedIrisGraft SurvivalIntraocular PressureAdultPostoperative ComplicationsAged, 80 and overArtificial OrgansTreatment OutcomeFollow-Up StudiesProsthesis ImplantationCorneal DiseasesIntraoperative ComplicationsSilicones