MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/jbhi.2026.3702259

Медицинская библиотека · IEEE journal of biomedical and health informatics · 2026

Cross-Tracer Synthesis Model of 11C-CFT and 18F-DOPA PET Images from 18F-FDG for Parkinson's Disease.

Yi Wenxiang, Sun Xiaolin, Sun Hao, Chang Yuan, Ye Zanting, Niu Xiaolong, Jiang Lei, Lu Lijun

СтатьяПеревод пока не подготовлен

Аннотация

Positron emission tomography (PET) with various tracers plays a critical role in Parkinson's disease (PD) studies. However, the clinical application of PET with novel or less-available tracers is limited by factors such as high cost and short half-life. To address this limitation, we developed a cross-tracer PET synthesis model based on diffusion model to directly synthesize cross-tracer PET images from widely used 18F-FDG PET images for PD studies. The network was initially trained on 18F-FDG and 11C-CFT datasets, and subsequently fine-tuned on 18F-FDG and 18F-DOPA datasets. After anonymization, synthetic images were mixed with real ones and underwent visual assessment by radiologists. Quantitative analyses were further performed through voxel-wise comparisons and regional error analysis between synthetic and real images. Visual assessment indicated that the synthetic 11C-CFT and 18F-DOPA PET images were comparable to real images in terms of quality, noise, and striatal conspicuity, with no significant differences observed in the error maps. Synthetic 11C-CFT images achieved an average PSNR of 36.22 and an SSIM of 0.96, whereas 18F-DOPA images yielded values of 29.79 and 0.95, respectively. Bland-Altman analysis indicated high consistency between synthetic and real images. The average standardized uptake value (SUV) bias was 0.013 $\pm$ 0.032 SUV for 11C-CFT and -0.175 $\pm$ 0.149 SUV for 18F-DOPA. The proposed cross-tracer PET synthesis model achieves comparable performance with 11C-CFT or 18F-DOPA PET imaging for PD studies.

Для цитирования: Yi Wenxiang, Sun Xiaolin, Sun Hao, Chang Yuan, Ye Zanting, Niu Xiaolong, Jiang Lei, Lu Lijun. Cross-Tracer Synthesis Model of 11C-CFT and 18F-DOPA PET Images from 18F-FDG for Parkinson's Disease.. IEEE journal of biomedical and health informatics. 2026. DOI: 10.1109/jbhi.2026.3702259.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.