Capturing human-machine interplay in automated insulin delivery systems through day-to-day variability of the automated correction index (ACI-V%).

Tumminia Andrea, Papa Giuseppe, Cannarella Rossella, Galeano Francesco, Oteri Vittorio, Amato Vincenzo, Baratta Roberto, Condorelli Rosita A, Palazzolo Roberto, Gusmano Carmelo, Finocchiaro Concetta, Gruttadauria Gianfranco, Presti Donatella Lo, Calabrisotto Salvatore Scirè, Anzaldi Massimiliano, Piticchio Tommaso, Vignera Sandro La, Frittitta Lucia, Frasca Francesco, Calogero Aldo E

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The Automated Correction Index (ACI) reflects the proportion of algorithm-driven correction boluses relative to total bolus insulin in advanced hybrid closed-loop (AHCL) systems. While mean ACI has been associated with glycemic outcomes in patients with type 1 diabetes mellitus (T1DM), the clinical significance of its day-to-day variability (ACI-V%) remains unknown.

METHODS

In this multicenter real-world study, 330 pediatric and adult patients with T1DM using the MiniMed™ 780G system were studied. ACI-V% was defined as the coefficient of variation of daily ACI values over a 30-day period. Associations between ACI-V% and continuous glucose monitoring (CGM) metrics were assessed.

RESULTS

Higher ACI-V% was associated with greater time in range (TIR70-180 mg/dL) and lower time above range, while no significant association with time below range was observed. ACI-V% showed an inverse correlation with mean ACI, suggesting greater day-to-day variability in settings of lower overall automated correction insulin delivery. Moreover, ACI-V% independently predicted achievement of TIR70-180 mg/dL > 70%, with a threshold of ≥ 32.6% identifying patients more likely to reach this target (sensitivity 52.4%, specificity 71.4%).

CONCLUSIONS

ACI-V% provides an exploratory descriptor of day-to-day variability in automated correction insulin delivery that may complement mean ACI for clinical interpretation of AHCL system behavior.

Для цитирования: Tumminia Andrea, Papa Giuseppe, Cannarella Rossella, Galeano Francesco, Oteri Vittorio, Amato Vincenzo, Baratta Roberto, Condorelli Rosita A, Palazzolo Roberto, Gusmano Carmelo, Finocchiaro Concetta, Gruttadauria Gianfranco, Presti Donatella Lo, Calabrisotto Salvatore Scirè, Anzaldi Massimiliano, Piticchio Tommaso, Vignera Sandro La, Frittitta Lucia, Frasca Francesco, Calogero Aldo E. Capturing human-machine interplay in automated insulin delivery systems through day-to-day variability of the automated correction index (ACI-V%).. Diabetes research and clinical practice. 2026. DOI: 10.1016/j.diabres.2026.113613.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.