MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00421-026-06469-2

Медицинская библиотека · European journal of applied physiology · 2026

Side differences in NIRS-derived muscle oxygen saturation during treadmill running.

Zwiener Lara, Richrath Oliver, Skotzke Philip, Volkamer-Kien Benjamin, Schwindling Sascha, Meyer Tim

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Near-infrared spectroscopy (NIRS) offers a promising non-invasive method to assess muscle oxygenation in real time. While asymmetries in muscle oxygen saturation (SmO2) between dominant and non-dominant legs have been studied in cycling, data in running are limited. Such differences may affect NIRS use in training control. This study investigated SmO2 differences between dominant and non-dominant vastus lateralis during treadmill running at three workloads using a wearable continuous-wave NIRS device.

METHODS

Forty-eight participants (20 female, Age = 21.6 ± 1.5 years) performed two graded treadmill exercise tests, 14 days apart. The Moxy Monitor was placed bilaterally on the vastus lateralis to measure SmO2 and analysed across three individualized workloads (LOW, MID, HIGH). Linear mixed models were used with participant as random, and side and workload as fixed effects. To assess adipose tissue thickness (ATT) effects, a 7mm cut-off defined two subgroups (ATT<7mm, ATT>7mm). Bland-Altman plots examined mean bias and limits of agreement.

RESULTS

No significant side effects were found for either group (ALL p = .759, ATT<7mm p = .713 and ATT>7mm p = .890). Bland-Altman analysis revealed a small mean bias (ALL: -0.34%, ATT<7mm: - 0.48%, ATT>7mm: -0.22%) with wide limits of agreement between the legs.

CONCLUSION

No systematic differences between SmO2 response between the legs were found. However, wide limits of agreement suggest that individual side differences may exist. A single NIRS device may sufficiently reflect bilateral SmO2 responses at the group level, while individual side-to-side-comparisons should be interpreted with caution.

Для цитирования: Zwiener Lara, Richrath Oliver, Skotzke Philip, Volkamer-Kien Benjamin, Schwindling Sascha, Meyer Tim. Side differences in NIRS-derived muscle oxygen saturation during treadmill running.. European journal of applied physiology. 2026. DOI: 10.1007/s00421-026-06469-2.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.