MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jbiotec.2026.10.004

Медицинская библиотека · Journal of biotechnology · 2026

Evaluation of Synthesized Borophene; Potential Toxicity on BAX/BCL-2, Il-1, and IL-10.

Bay Mehmet, Genc Sidika, Rouhi Sina, Karabulut Kubra, Nigde Esmanur, Ay Feridun, Perkgoz Nihan Kosku, Taghizadehghalehjoughi Ali

СтатьяПеревод пока не подготовлен

Аннотация

Borophene was grown on glass coverslip substrates by chemical vapor deposition (CVD) to investigate its effects on fibroblast viability and selected oxidative stress, apoptosis-related, and inflammatory markers. The deposited films were characterized using optical microscopy, scanning electron microscopy, energy-dispersive X-ray spectroscopy, Raman spectroscopy, X-ray diffraction, and atomic force microscopy. Surface imaging revealed film coverage across the examined regions, and atomic force microscopy indicated a representative thickness of approximately 27nm. L929 fibroblasts were cultured on borophene-coated glass coverslips, and cellular responses were evaluated after 24h using the MTT assay, total antioxidant capacity (TAC), total oxidant status (TOS), and measurements of BAX, BCL-2, IL-1, and IL-10. Cell viability was 90.84% relative to the control, with no statistically significant difference reported. TAC, TOS, and BAX also showed no statistically significant changes. In contrast, BCL-2 levels increased significantly (P < 0.001), suggesting a potential adaptive or anti-apoptotic response. These findings provide preliminary evidence of limited short-term cytotoxicity under the tested conditions. However, the increased BCL-2 level alone does not establish functional cytoprotection, and further studies are needed to clarify the underlying mechanisms and longer-term biological effects.

Для цитирования: Bay Mehmet, Genc Sidika, Rouhi Sina, Karabulut Kubra, Nigde Esmanur, Ay Feridun, Perkgoz Nihan Kosku, Taghizadehghalehjoughi Ali. Evaluation of Synthesized Borophene; Potential Toxicity on BAX/BCL-2, Il-1, and IL-10.. Journal of biotechnology. 2026. DOI: 10.1016/j.jbiotec.2026.10.004.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.