Efficacy and Safety of an Insulin Patch Pump Compared to Multiple Daily Injections in Pediatric Patients With Diabetes: A Randomized, Open-Label, Crossover, Non-Inferiority Clinical Trial.

Fu Junfen, Wu Jin, Hui Yao, Zhu Weiwei, Novihoho Maudline Abra

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Insulin patch pumps offer advantages over multiple daily injections (MDI) for pediatric diabetes, but randomized trial evidence in Chinese children remains limited.

OBJECTIVES

To evaluate the efficacy and safety of a tubeless insulin patch pump (Equil™) compared with MDI in children and adolescents with diabetes.

METHODS

This multicenter, open-label, randomized, crossover, non-inferiority trial was conducted at seven pediatric endocrinology centers in China (September 2021 - October 2022). Patients aged 3-17 years with type 1 diabetes mellitus (T1DM) or type 2 diabetes mellitus (T2DM) were randomized 1:1 to receive continuous subcutaneous insulin infusion (CSII) via Equil™ or MDI via insulin pen for 5 days, followed by crossover. The primary outcome was mean blood glucose (MBG). Non-inferiority margin was pre-specified as 0.386 mmol/L. Secondary outcomes included glycemic variability (standard deviation of blood glucose, SDBG), glycated albumin (GA), total daily insulin dose (TDD), hypoglycemia frequency, and adverse events. Patient satisfaction was assessed using a study-specific 11-item questionnaire.

RESULTS

Of 74 enrolled patients, 72 (97.3%) completed the study. CSII demonstrated non-inferiority to MDI for MBG (8.43±1.88 mmol/L, n=74, vs 9.00±2.04 mmol/L, n=72); mean difference -0.606 mmol/L; 95% CI -0.988 to -0.223; upper CI limit -0.223 < non-inferiority margin 0.386. No significant differences were observed for secondary outcomes (SDBG: 3.019 vs 3.357; GA change: 2.52±3.03% vs 2.02±3.25%, p=0.184; TDD: 132.17±78.43 vs 147.52±91.59 IU, p=0.159; hypoglycemia events: 114 vs 106). Adverse event rates were similar (75.7% vs 69.4%, p=0.399); no serious adverse events occurred. Patient satisfaction was significantly higher with CSII (total score 21.03±4.47 vs 22.00±3.99; mean difference -0.97, 95% CI -1.75 to -0.19; p=0.015), with 68.1% of patients preferring the patch pump.

CONCLUSION

The Equil™ patch pump is non-inferior to MDI in terms of glycemic control and safety for pediatric diabetes patients, with higher patient satisfaction. These findings support the patch pump as an effective alternative for children and adolescents requiring exogenous insulin therapy.

Для цитирования: Fu Junfen, Wu Jin, Hui Yao, Zhu Weiwei, Novihoho Maudline Abra. Efficacy and Safety of an Insulin Patch Pump Compared to Multiple Daily Injections in Pediatric Patients With Diabetes: A Randomized, Open-Label, Crossover, Non-Inferiority Clinical Trial.. Clinical medicine insights. Endocrinology and diabetes. 2026. DOI: 10.1177/11795514261486607.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.