MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fsurg.2026.1959554

Медицинская библиотека · Frontiers in surgery · 2026

A "stepped" flexible vacuum-assisted ureteral access sheath improves stone clearance efficiency: experimental results from an ex vivo porcine model.

Lv Daibing, Jin Ming, Meng Xi, Zhang Weizhong, Yuan Shanfang, Ding Yang, Wang Weixi, Yang Jianghua, Liao Xiaoxing

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the impact of a novel "stepped" flexible vacuum-assisted ureteral access sheath (SFV-UAS) on stone clearance efficiency during flexible ureteroscopy lithotripsy (f-URL).

METHODS

Human upper urinary tract stone fragments (< 4 mm) were placed into ex vivo porcine renal pelves. We simulated f-URL stone extraction under continuous irrigation and vacuum suction, comparing the SFV-UAS (ureteral segment 12/14 Fr, cystourethral segment 16/18 Fr) with a conventional flexible vacuum-assisted ureteral access sheath (FV-UAS)(12/14 Fr). With intrarenal pressure strictly controlled (< 30 mmHg) and constant vacuum suction (01 step), irrigation flow rates were evaluated at 40 mL/min, 50 mL/min, 60 mL/min, 70 mL/min, 80 mL/min, and 90 mL/min. Stone evacuation times were recorded.

RESULTS

(1) Sheath type and irrigation flow rate exhibited significant main effects on clearance time [F(1,408) = 189.231, P < 0.01, effect size 31.7%; and F(5,408) = 38.721, P < 0.01, effect size 32.2%, respectively]. A significant two-way interaction was also observed [F(5,408) = 8.372, P < 0.01, effect size 9.3%]. (2) Simple main effects revealed: First, across all corresponding irrigation rates, the SFV-UAS group achieved significantly shorter clearance times than the FV-UAS group (mean differences: MD = -21.598, -18.099, -8.172, -11.129, -9.762, -4.883; all P < 0.05). Second, within the SFV-UAS group, rates ≥ 70 mL/min resulted in significantly shorter clearance times vs. the 40 mL/min baseline (mean differences:MD = -9.393, -9.771, -9.084; all P < 0.05). Although comparisons between 60 mL/min and higher rates were non-significant, 70 mL/min was the lowest evaluated irrigation rate that demonstrated a statistically significant reduction in clearance time compared to the 40 mL/min baseline. Third, within the FV-UAS group, clearance times at ≥ 60 mL/min were significantly shorter than at 40 and 50 mL/min (mean differences:MD = -19.664, -12.370; all P < 0.001), with no significant differences among the ≥ 60 mL/min groups, indicating its plateau at ≥ 60 mL/min.

CONCLUSION

Within the parameters of this ex vivo model,the SFV-UAS significantly reduces the measured stone clearance time during f-URL compared to the FV-UAS under identical irrigation conditions. For the SFV-UAS group, targeting an irrigation flow rate of ≥ 70 mL/min consistently optimizes stone extraction efficiency relative to baseline conditions.

Для цитирования: Lv Daibing, Jin Ming, Meng Xi, Zhang Weizhong, Yuan Shanfang, Ding Yang, Wang Weixi, Yang Jianghua, Liao Xiaoxing. A "stepped" flexible vacuum-assisted ureteral access sheath improves stone clearance efficiency: experimental results from an ex vivo porcine model.. Frontiers in surgery. 2026. DOI: 10.3389/fsurg.2026.1959554.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.