MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6ay01422d

Медицинская библиотека · Analytical methods : advancing methods and applications · 2026

An all-in-one analytical platform for rapid determination of toxic dyes in complex water by SERS and machine learning.

Gao Jie, Yu Qian, Guan Zhiwen, Zhang Weiwei, Guo Jiaqi, Kong Xianming

СтатьяПеревод пока не подготовлен

Аннотация

Rapid and reliable determination of toxic dyes in complex aqueous environments remains challenging because matrix interference and complicated sample pretreatment often compromise analytical accuracy and practical applicability. Therefore, an integrated filtration-adsorption-SERS sensing platform coupled with one-dimensional convolutional neural network (1D-CNN) modeling was fabricated for rapid and quantitative detection of malachite green (MG) and methylene blue (MB) in complex water samples. Polypropylene filter cloth (PPFC) served as a porous fibrous support for sample filtration, while Ag nanoparticles (Ag NPs) were uniformly immobilized on the fiber surfaces via a seed-mediated in situ growth strategy to provide SERS-active sites. Activated carbon was incorporated into the PPFC/Ag filter configuration to provide adsorption of the target dyes during sample treatment. The resulting configuration integrates filtration, adsorption, and SERS detection within a common analytical workflow, while 1D-CNN modeling was employed for quantitative analysis of the acquired SERS spectra. Benefiting from the integrated filtration-adsorption configuration and porous fibrous architecture, the platform exhibited high signal uniformity and favorable analytical performance, with detection limits of 10-9 M for both MG and MB. Adsorption kinetic analysis demonstrated that dye removal followed the pseudo-second-order model, with equilibrium removal efficiencies of 99.7% for MB and 98.6% for MG. To improve quantitative reliability in complex matrices, a 1D-CNN model was employed for SERS spectral analysis, yielding high accuracy with R2 values of 0.992 and 0.982 for MB and MG, respectively, with low prediction errors. Furthermore, spiked Moyan Lake water samples showed recoveries of 98.14% and 96.37% for MB and MG, respectively, with RSD values of 4.53% and 4.91%, demonstrating satisfactory accuracy and precision in a real water matrix. By integrating these complementary functions within the same filtration configuration, the proposed platform establishes a continuous analytical workflow from sample filtration and adsorption to SERS detection and quantitative analysis. This integrated design simplifies the conventional multi-step procedure and provides a sensitive, reliable, and practical approach for rapid monitoring of trace organic dyes in complex water matrices.

Для цитирования: Gao Jie, Yu Qian, Guan Zhiwen, Zhang Weiwei, Guo Jiaqi, Kong Xianming. An all-in-one analytical platform for rapid determination of toxic dyes in complex water by SERS and machine learning.. Analytical methods : advancing methods and applications. 2026. DOI: 10.1039/d6ay01422d.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.