DOI 10.1007/s11060-026-05827-6
MRI-based preoperative WHO grade prediction in meningioma: development and comparison of deep learning, radiomics, clinical, and combined models in multicenter data.
Аннотация
PURPOSE: The objective of this study was to develop and externally validate complementary magnetic resonance imaging (MRI)-based models and their stacked combinations for preoperative World Health Organization (WHO) grading of intracranial meningioma.
METHODS
This retrospective multicenter study included 455 histopathologically confirmed meningiomas: a four-center development cohort (n = 346) with leave-one-center-out cross-validation and an external cohort (n = 109). Four base models used contrast-enhanced T1-weighted MRI: tumor + peritumoral radiomics, an nnU-Net segmentation-based classifier, frozen DINOv3 transfer-learning features, and clinical variables. All 15 combinations were prespecified and stacked using a linear meta-learner trained on development out-of-fold predictions. Frozen models were externally evaluated without modification.
RESULTS
WHO 2-3 tumors comprised 24.6% overall (112/455; development 20.5%; external 37.6%). External AUCs were 0.732 for nnU-Net, 0.703 for DINOv3, 0.645 for clinical, 0.628 for radiomics. The multimodal ensemble (nnU-Net+DINOv3+Clinical) achieved the highest external AUC (0.742), exceeding radiomics (ΔAUC +0.114, p = 0.008) but not nnU-Net (ΔAUC +0.011, p = 0.737). Compared with the clinical model, discrimination was higher but nonsignificant at the prespecified threshold (ΔAUC +0.098, p = 0.050), while reclassification improved (IDI +0.109, p < 0.001). Radiomics-containing combinations performed strongly in development but lost most discrimination externally. The multimodal ensemble had an external calibration slope of 1.32 (Brier 0.190) and net benefit above default strategies at thresholds ≥ 0.23.
CONCLUSION
The multimodal ensemble achieved the highest external AUC but did not significantly exceed nnU-Net, which was the most transportable single predictor of meningioma grade. Clinical variables did not improve discrimination but enabled interpretable feature-level attribution. Handcrafted radiomics lacked external transportability.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.