DOI 10.1007/s00256-026-05389-8
Acute glenoid rim fractures: reliability of linear and surface area methods for CT-based bone loss assessment.
Аннотация
OBJECTIVE
We wanted to investigate and compare the reliability of two measuring methods for glenoid bone loss, one linear- and one surface area method, in acute glenoid fractures after dislocation. This was an experimental study.
METHOD: Thirty CT-shoulder scans in patients with an acute glenoid rim fracture were measured in a lateral"en face" view in 2D and 3D by two independent assessors. In 10 of 30 patients contralateral shoulder CT-scan was obtained for reference circle placement. Intra- and interrater reliability was analysed by Intra Class Correlation. Wilcoxon signed rank test was performed for comparison of bone loss estimates between methods.
RESULTS
The reliability ranged from 0.85 to 0.97 for the two methods in both 2D and 3D, which is considered good to excellent. The bone loss estimates were significantly larger with linear method than area method. Drawing of a best-fitting-circle had a good reliability between assessors.
CONCLUSIONS
Linear- and surface area methods demonstrated comparable reliability in assessing glenoid bone loss in acute fractures and we found no difference between 2D- and 3D-modalities. However, linear methods may overestimate defect in cases with irregular fracture lines, suggesting area method may be preferable in acute fractures.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.