DOI 10.1016/j.burns.2026.108230
Optimising thermal imaging for clinical assessment of burn depth and healing monitoring.
Аннотация
BACKGROUND
Infrared thermography (IRT) is a promising method for burn depth assessment and monitoring of wound healing. However, its clinical application is limited by the absence of standardised imaging and processing protocols. This study aimed to optimise thermal image analysis for heterogeneous burns and to develop a quantitative model for burn depth assessment and monitoring of wound progression using IRT.
METHODS
A prospective longitudinal cohort study was conducted at a burn centre in Kharkiv, Ukraine. Patients were examined using a self-developed infrared camera (array 384 × 288, 0.07 °C sensitivity, 1 mrad spatial resolution). Temperature parameters of burns recorded within three days post-injury were used to develop a prognostic model, with final clinical outcome serving as the reference standard. Prognostic performance was assessed by ROC analysis. Burn healing was monitored by changes in the relative temperature of the wound.
RESULTS
Sixty-five adults with 115 burn wounds were enrolled. Of 65 wounds assessed within the first three days, 48% healed within 21 days, while 52% did not heal or underwent skin grafting within 21 days. A relative temperature threshold of ΔTcut-off = -2.4 °C (p < 0.00001) distinguished deep dermal and full-thickness burns (τ ≥ 21 days) from superficial and mixed burns. The prognostic model demonstrated 83.3% sensitivity, 94.4% specificity, and AUC = 0.942. Agreement between prognostic and observed outcomes was substantial (Cohen's ϰ = 0.84).
CONCLUSIONS
The proposed thermal image processing enabled objective assessment of burn depth and facilitated non-invasive monitoring of wound healing. The developed model showed high prognostic performance and substantial agreement with the final clinical outcomes. Further validation in larger prospective cohorts is needed to support the development of standardised protocols.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.