MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00784-026-07219-6

Медицинская библиотека · Clinical oral investigations · 2026

Static and fatigue behavior of one- and two-piece zirconia implant abutment systems: an in vitro study.

Diaz Pedro, Lopez Monica, Villagra Luis J Gil, Del Real Juan Carlos, Mosaddad Seyed Ali, Suarez Maria J

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare static fracture behavior, fatigue survival, and fracture patterns of three one- and two-piece zirconia implant abutment systems.

MATERIALS AND

METHODS

Three groups comprised 48 assemblies each: (1) Astra Tech ZirDesign, one-piece zirconia; (2) Biomet 3i CAP454, two-piece zirconia with a titanium base; and (3) Straumann RC Anatomic, one-piece zirconia. Within each group, 12 assemblies underwent initial static testing and 12 each underwent fatigue at 25%, 50%, or 75% of the system-specific reference load (10 Hz, approximately 30°, five million cycles). Static outcomes underwent one-way and Welch analyses of variance; pooled run-out proportions underwent exact tests (α = 0.05).

RESULTS

Mean static fracture loads were 1058 ± 225 N (Astra Tech), 866 ± 189 N (Biomet 3i), and 873 ± 402 N (Straumann), without a significant difference (p = .194). Calculated tensile-side stress differed (p = .016); compressive-side findings were method-dependent. Run-out was 88.9% at 25% (32/36; 95% confidence interval, 73.9%-96.9%) and 0% at higher levels (p < .001). Residual fracture outcomes described survivors only. Fractography indicated brittle cervical failure.

CONCLUSIONS

Static fracture-load superiority was not demonstrated. Fatigue run-out varied with relative loading; modeled stress differences do not establish intrinsic material-strength differences.

CLINICAL RELEVANCE: These system-specific laboratory results cannot isolate an independent titanium-base effect or establish clinical service life.

Для цитирования: Diaz Pedro, Lopez Monica, Villagra Luis J Gil, Del Real Juan Carlos, Mosaddad Seyed Ali, Suarez Maria J. Static and fatigue behavior of one- and two-piece zirconia implant abutment systems: an in vitro study.. Clinical oral investigations. 2026. DOI: 10.1007/s00784-026-07219-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.