Long-Term Safety and Procedural Performance of an Interatrial Shunt for Heart Failure According to Ejection Fraction.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rodés-Cabau Josep, Stone Gregg W, Kar Saibal, Verheye Stefan, Roguin Ariel, Bax Jeroen, Bayes-Genis Antoni, Nunez Julio, Depta Jeremiah, Laufer-Perl Michal, Moravsky Gil, Romero Alicia, Prihadi Edgard, Chung Eugene S, Price Matthew J, Chenier Michael, Schewel Dimitry, Kumar Sachin, Kische Stephan, Bhatt Kunjan, Shah Kevin S, Donovan Daniel J, Hendrix Suzanne, O'Keefe Patrick, Abraham William T, Zile Michael R, Anker Stefan D, Eigler Neal L, Lindenfeld JoAnn, RELIEVE-HF Investigators

Аннотация

BACKGROUND: Long-term device durability and phenotype-specific safety outcomes after interatrial shunting require further characterization.

OBJECTIVES: This study aimed to evaluate the procedural success, device durability, and heart failure (HF) phenotype-specific safety outcomes of an interatrial shunt in the RELIEVE-HF trial.

METHODS: Randomized patients were assigned 1:1 to shunt or sham control with prespecified stratification by left ventricular ejection fraction (LVEF) into heart failure with reduced ejection fraction (HFrEF) (LVEF ≤40%) and heart failure with preserved ejection fraction (HFpEF) (LVEF >40%). Procedural performance, device durability, serious adverse events (SAEs), major adverse cardiovascular or neurological events (MACNE), major bleeding, and renal outcomes were assessed through 2 years.

RESULTS: Among 605 enrolled patients (508 randomized; 97 roll-in), shunt implantation was attempted in 370 and was successful in 369 (99.7%). Among implanted patients with follow-up (n = 348), no device- or procedure-related MACNE occurred through 2 years (0%; 95% CI: 0%-0.9%), and shunt patency was 99.4% (95% CI: 97.9%-99.9%). Prespecified LVEF-stratified analyses demonstrated divergent safety profiles. In HFrEF, shunt therapy was not associated with excess all-cause MACNE, major bleeding, or renal decline and was associated with lower SAE burden. In HFpEF, shunt therapy was associated with higher all-cause MACNE, greater SAE burden, increased major bleeding, and greater renal decline.

CONCLUSIONS: Interatrial shunt implantation was mechanically reliable and durable through 2 years. Safety outcomes differed by HF phenotype, with no evidence of excess clinical safety events in HFrEF but increased adverse events in HFpEF. These findings support phenotype-specific evaluation of interatrial shunt therapy. (REducing Lung congestion symptoms using the v-wavE shunt in adVancEd Heart Failure [RELIEVE-HF]; NCT03499236).