From Benchtop to Handheld Systems: Calibration Transfer for On-Site NIR System Butter Quality Monitoring.

Serva Lorenzo, Calore Andrea, Segato Severino, Ferrari Veronica, Rungchang Saowaluk, Berzaghi Paolo, Cozzi Giulio

СтатьяПеревод пока не подготовлен

Аннотация

Butter quality assessment requires rapid and reliable portable analytical tools that enable on-site analysis beyond specialized food laboratories. This study evaluated the transfer of calibration models developed on a benchtop Near-Infrared (NIR) instrument (DS25) to three handheld NIR devices (Aurora, JDSU and ISC) for the prediction of butter compositional traits and fatty acid profile. Ninety-nine butter samples from different milk production systems were used for spectral acquisition and calibration development. Different calibration transfer (CT) strategies, including spectral bias correction (SBC), direct standardization (DS), piecewise direct standardization (PDS), Shenk-Westerhaus (S-W) standardization and dynamic orthogonal projection (DOP), were combined with Partial Least Squares (PLS) regression and evaluated on a hold-out validation set. Across both hold-out validation and prediction-based consistency analyses, Aurora and JDSU showed the most robust performance relative to the DS25 benchmark and the multi-instrument consensus, particularly for moisture, fat content, and major fatty acids (FA) groups, whereas ISC showed lower and more variable performance. The outcomes suggested that handheld NIR spectroscopy, supported by appropriate calibration transfer and limited target-instrument updating, can be used for rapid and decentralized butter quality monitoring. However, transfer success was instrument-, variable- and method-dependent, confirming the need for device-specific validation before routine application.

Для цитирования: Serva Lorenzo, Calore Andrea, Segato Severino, Ferrari Veronica, Rungchang Saowaluk, Berzaghi Paolo, Cozzi Giulio. From Benchtop to Handheld Systems: Calibration Transfer for On-Site NIR System Butter Quality Monitoring.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26196110.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.