MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.saa.2026.128964

Медицинская библиотека · Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026

Reference-state transferability limits in IR140: working-solution spectroscopy, bleachable optical depth, and apparent femtosecond saturation.

Liu Chao, Li Yong, You Yuhang, Gao Yue, Zhang Fan, Wan Yan, Zhao Hongkai, Li Zhiqiang, Li Jing, Yue Xianfang, Jin Bing

СтатьяПеревод пока не подготовлен

Аннотация

Aggregation-sensitive nonlinear absorbers are often characterised using dilute spectroscopic references, although their highly loaded nonlinear-optical (NLO) formulations may occupy different states. Here, IR140 is used to test whether reference-state assignments remain transferable to 800 nm femtosecond measurements. UV-visible-near-infrared absorption, steady-state photoluminescence, absolute photoluminescence quantum yield (PLQY), streak-camera time-resolved photoluminescence, and open-aperture Z-scan/I-scan measurements were combined with a unified finite-depth slow-absorber model. The dilute methanol-stock series develops a broad blue-shifted branch near 700-800 nm, whereas aqueous NLO solutions prepared from a dimethyl sulfoxide (DMSO) stock display a distinct red-shifted branch near 1000 nm. Thus, nominal solvent identity and a dilute spectrum do not uniquely define the formulation used for nonlinear measurement. Unified analysis yields apparent saturation fluences of 86.5-312.8 μJ cm-2 in methanol, 168.4 μJ cm-2 in DMSO, and 225.5-444.0 μJ cm-2 in aqueous formulations; the overlapping ranges show that solvent ranking alone is insufficient. These values are model-conditioned estimates rather than independent-preparation averages. Along the methanol-stock reference branch, PLQY decreases from 14.55% to 0.08%, while the monitored near-infrared emissive channel shortens markedly. The measured picosecond emissive relaxation is too slow to control bleaching within a 35 fs pulse, although unobserved ultrafast non-emissive channels cannot be excluded. We therefore establish an IR140-specific reference-to-working-state audit: when spectra are not equivalent, the low-fluence transmittance T0 must be fixed from the formulation-matched working solution, and comparisons should be restricted to equivalent formulations or explicitly model the mismatch.

Для цитирования: Liu Chao, Li Yong, You Yuhang, Gao Yue, Zhang Fan, Wan Yan, Zhao Hongkai, Li Zhiqiang, Li Jing, Yue Xianfang, Jin Bing. Reference-state transferability limits in IR140: working-solution spectroscopy, bleachable optical depth, and apparent femtosecond saturation.. Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy. 2026. DOI: 10.1016/j.saa.2026.128964.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.