Медицинская библиотека · Aesthetic surgery journal · 2026

Breast Implant Flipping: Prevalence, Clinical Correlation, and Independent Risk Factors in a Consecutive Ultrasound Cohort.

McGuire Patricia, Glicksman Caroline, Gabriel Allen, Lawrence Marisa, Haws Melinda, Wall Holly, Wall Simeon, Bresnick Steven

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Silicone breast implants are designed with an anterior domed surface, and relatively flat posterior surface that contains the cured silicone patch. With implant flipping (an anterior-posterior malposition), the posterior patch rotates to an anterior position.

OBJECTIVES

There are currently no prospective published studies reporting the prevalence of implant flipping and its associated symptoms in aesthetic patients. This prospective study used in-office high-resolution ultrasound (HRUS) to evaluate the prevalence of breast implant flipping, assess associated changes in breast shape, appearance, and symptoms, and identify potential risk factors.

METHODS

Consecutive patients with silicone breast implants presenting for routine follow-up underwent HRUS at 7 study sites in the United States over a 4-month period between April 1st and August 1st, 2026. Demographic data included age and BMI. Implant data included time since surgery, whether a primary of revision procedure, number of revisions, manufacturer, size, style, surface, use of ADM or scaffold, pocket location, capsule grade, flipped or not, and rupture.

RESULTS

Five hundred and ninety consecutive patients were enrolled over 4 months. Mean age 43 years with range 22-82, mean BMI 23 with range of 16-34.5. Primary augmentations accounted for 64.6% of procedures, while revision augmentations accounted for 35.4%. Device manufacturer distribution, 63.9% Allergan, 12.4% Mentor, 15.9% Motiva, and 7.1% Sientra. Implant flipping was identified in 75 patients (12.7%).

CONCLUSIONS

Implant flipping was identified by HRUS in one in eight patients. Larger implant volume, prepectoral placement, and lack of soft tissue support were independently associated with flipping. HRUS improves detection, patient counseling, and surgical planning.

Для цитирования: McGuire Patricia, Glicksman Caroline, Gabriel Allen, Lawrence Marisa, Haws Melinda, Wall Holly, Wall Simeon, Bresnick Steven. Breast Implant Flipping: Prevalence, Clinical Correlation, and Independent Risk Factors in a Consecutive Ultrasound Cohort.. Aesthetic surgery journal. 2026. DOI: 10.1093/asj/sjag235.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.