MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fmed.2026.1908302

Медицинская библиотека · Frontiers in medicine · 2026

Pulmonary hypertension optimal screening in interstitial lung disease (PHOS-ILD): a scoring system for the detection of pulmonary hypertension in patients with interstitial lung disease.

Karampitsakos Theodoros, Wasserman Evan, Stagaki Eleni, Thottassery Abhay, Smith Jorden, Asif Huda, Soto Brian, Arce Guzman Christian, Hammonds Jalen, Papasarantou Anna, Bakakos Agamemnon, Papaioannou Ourania, Matsioulas Apostolos, Karakontaki Foteini, Loverdos Konstantinos, Kefalidou Eirini, Juan-Guardela Brenda M, Herazo-Maya Jose D, Tonelli Adriano R, Bandyopadhyay Debabrata

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary hypertension (PH) is a common comorbidity of interstitial lung disease (ILD). Timely detection may improve outcomes through implementation of PH specific treatments.

METHODS

Retrospective, multicenter study aiming to identify features that predict PH in patients with ILD. In the derivation cohort (ILD cohort-University of South Florida), we identified predictors of PH in ILD and created a scoring system using the rounded value of odds ratio for each significant parameter. Correlation with hemodynamic parameters was investigated in the derivation and validation cohort (Idiopathic Pulmonary Fibrosis cohort-Cleveland Clinic).

RESULTS

We included 164 patients with ILD that underwent right heart catheterization (RHC) [derivation cohort: n = 118, median age (years, 95% CI): 69.0 (65.9-71.0), female gender: 65 (54.6%), median mean pulmonary arterial pressure (mPAP) (mmHg, 95% CI): 25.0 (23.0-27.0), median pulmonary vascular resistance (PVR) [Wood units (WU), 95% CI]: 3.6 (3.0-4.3), validation cohort: n = 46, median age (95% CI): 63.0 (60.0-66.0), female gender: 17 (37%), median mPAP (mmHg, 95% CI): 20.5 (18.0-27.2), median PVR (WU, 95% CI): 3.1 (2.2-3.4)]. Parameters and optimal cut-offs that significantly predicted precapillary PH in the derivation cohort were: age>42 years, heart rate recovery (HRR) at 1 min ≤ 15 bpm in 6-min walk test (6 MWT), 6-min walk distance (6 MWD) ≤ 270 meters, B-type natriuretic peptide (BNP) > 136 pg/mL, pulmonary artery to ascending aorta diameter ratio (PA/AA) > 1 in high-resolution computed tomography (HRCT), main PA diameter > 29 mm in HRCT, right ventricular systolic pressure > 42 mmHg on echocardiogram. We created a PH detection model that ranged from 0 to 28. The optimal cut-off threshold for the detection of PH was > 14 (80% sensitivity, 68% specificity, AUC: 0.78). A simplified scoring system without BNP and main PA diameter (range: 0-21) maintained the same AUC. The simplified scoring system exhibited positive correlation with mean pulmonary artery pressure both in the derivation (rho = 0.47, p < 0.0001) and validation cohort (rho = 0.36, p = 0.013).

CONCLUSION

This study demonstrates that incorporation of demographic, functional, imaging, and echocardiographic characteristics can optimize the early identification of precapillary PH in patients with ILD, paving the way to structured screening strategies. Timely detection of PH might lead to timely implementation of emerging PH specific treatments in patients with ILDs.

Для цитирования: Karampitsakos Theodoros, Wasserman Evan, Stagaki Eleni, Thottassery Abhay, Smith Jorden, Asif Huda, Soto Brian, Arce Guzman Christian, Hammonds Jalen, Papasarantou Anna, Bakakos Agamemnon, Papaioannou Ourania, Matsioulas Apostolos, Karakontaki Foteini, Loverdos Konstantinos, Kefalidou Eirini, Juan-Guardela Brenda M, Herazo-Maya Jose D, Tonelli Adriano R, Bandyopadhyay Debabrata. Pulmonary hypertension optimal screening in interstitial lung disease (PHOS-ILD): a scoring system for the detection of pulmonary hypertension in patients with interstitial lung disease.. Frontiers in medicine. 2026. DOI: 10.3389/fmed.2026.1908302.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.