Contrast-Enhanced Ultrasonography of Orbital and Intraocular Pathologies in 24 Dogs and 6 Cats.

Ortner Janneke I, Hittmair Katharina M, Nell Barbara, Blohm Klaas-Ole

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Contrast-enhanced ultrasonography (CEUS) is a noninvasive and relatively safe imaging technique to assess ocular perfusion, showing high sensitivity and specificity for tumor characterization in human oncology, while reports on its application in canine and feline diseased eyes are limited. This study aimed to describe the CEUS features of orbital and intraocular pathologies in dogs and cats in order to evaluate its diagnostic value in detecting and characterizing various lesions.

ANIMAL STUDIED: CEUS examinations of 30 animals (24 dogs, 6 cats) were evaluated retrospectively.

PROCEDURES: Following B-mode ultrasonography, CEUS examinations utilizing sulfur hexafluoride were performed. Pathologies were categorized in one of the following groups: orbital neoplastic lesions, orbital inflammatory lesions, intraocular neoplastic lesions, intraocular inflammatory lesions and retinal detachment. Qualitative perfusion parameters, contrast intensity, enhancement pattern, perfusion type and time to wash-in and wash-out were evaluated.

RESULTS

CEUS detected vascularization in orbital and intraocular pathologies, with variable enhancement characteristics. Persistent vascularization was observed in all cases of retinal detachment. In orbital and intraocular neoplastic lesions, CEUS improved lesion localization, assessment of interactions with surrounding tissues and tissue perfusion. For inflammatory pathologies such as abscesses, myositis, and steatitis, the additional diagnostic value of CEUS compared to B-mode ultrasonography was limited.

CONCLUSION

Findings indicated that CEUS could identify a variety of orbital and intraocular pathologies and provided additional diagnostic information to B-mode ultrasonography, particularly for assessing neoplastic lesions and retinal detachments. CEUS has the potential to enhance ophthalmic ultrasonography in differentiating specific pathologies. Prospective studies are warranted to further evaluate its clinical use.

Для цитирования: Ortner Janneke I, Hittmair Katharina M, Nell Barbara, Blohm Klaas-Ole. Contrast-Enhanced Ultrasonography of Orbital and Intraocular Pathologies in 24 Dogs and 6 Cats.. Veterinary ophthalmology. 2026. DOI: 10.1111/vop.70281.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.