MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajpc.2026.101732

Медицинская библиотека · American journal of preventive cardiology · 2026

Heart failure and atrial fibrillation prediction from non-gated chest CT scans using AI-based cardiac chamber volumetry: an AI-CVD study within the multi-ethnic study of atherosclerosis (MESA).

Mirjalili Seyed Reza, Atlas Kyle, Reeves Anthony P, Zhang Chenyu, Wasserthal Jakob, Azimi Amir, Hashemi Ali, Mozafarybazargany Mohammadhossein, Ghaffari Jolfayi Amir, Atlas Thomas, Henschke Claudia I, Yankelevitz David F, Zulueta Javier J, Fan Wenjun, Mechanick Jeffrey I, Branch Andrea D, Nasir Khurram, Fayad Zahi, McConnell Michael V, Rana Jamal S, Vliegenthart Rozemarijn, Maron David J, Narula Jagat, Budoff Matthew J, Mehran Roxana, Williams Kim A, Shah Prediman K, Mechanic Oren, Agatston Arthur S, Kloner Robert A, Wong Nathan D, Naghavi Morteza

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We previously demonstrated that AI-derived cardiac chamber volumetry in ECG-gated CT scans predicts atrial fibrillation (AF) and heart failure (HF). Since most chest CTs are non-gated, and the American Heart Association recently highlighted their value for opportunistic cardiovascular risk assessment using AI-based coronary artery calcium scoring, we extended this concept to evaluate whether AI-derived chamber volumetry from non-gated CTs can reliably predict HF and AF.s.

METHODS

We compared AI-derived chamber volumetry from non-gated and ECG-gated chest CTs in 2053 Multi-Ethnic Study of Atherosclerosis (MESA) Exam 5 participants using mean and standard-deviation of absolute differences, intraclass correlation coefficients (ICC), and Cohen's κ. Variability between paired ECG-gated scans was determined by analyzing scans acquired 2 min apart in 5749 MESA Exam 1 participants. Predictive performance for incident HF and AF was compared using cumulative incidence curves, age- and sex-adjusted C-indices, and non-inferiority testing (δ=0.05).

RESULTS

Non-gated scans demonstrated excellent overall agreement with ECG-gated scans, with comparable performance for detecting cardiac chamber enlargement (98.8-99.2%, κ=0.76-0.84), relative to agreement observed between paired ECG-gated scans (98.6-98.9%, κ=0.72-0.77). Cumulative incidence curves for HF and AF stratified by quartiles showed substantial overlap. Age- and sex-adjusted C-indices were comparable for left atrial volume (0.75 vs 0.74, p = 0.001, non-inferiority p < 0.001), ventricular volume (both 0.77, p = 0.97, non-inferiority p < 0.001), and ventricular ratio (both 0.74, p = 0.57, non-inferiority p < 0.001) in predicting AF and HF.

CONCLUSION

AI-based evaluation of non-gated chest CT may provide reliable cardiac chamber volumetry and cardiovascular outcome prediction, enabling opportunistic screening for HF and AF risk.

Для цитирования: Mirjalili Seyed Reza, Atlas Kyle, Reeves Anthony P, Zhang Chenyu, Wasserthal Jakob, Azimi Amir, Hashemi Ali, Mozafarybazargany Mohammadhossein, Ghaffari Jolfayi Amir, Atlas Thomas, Henschke Claudia I, Yankelevitz David F, Zulueta Javier J, Fan Wenjun, Mechanick Jeffrey I, Branch Andrea D, Nasir Khurram, Fayad Zahi, McConnell Michael V, Rana Jamal S, Vliegenthart Rozemarijn, Maron David J, Narula Jagat, Budoff Matthew J, Mehran Roxana, Williams Kim A, Shah Prediman K, Mechanic Oren, Agatston Arthur S, Kloner Robert A, Wong Nathan D, Naghavi Morteza. Heart failure and atrial fibrillation prediction from non-gated chest CT scans using AI-based cardiac chamber volumetry: an AI-CVD study within the multi-ethnic study of atherosclerosis (MESA).. American journal of preventive cardiology. 2026. DOI: 10.1016/j.ajpc.2026.101732.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.