MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2026.346241

Медицинская библиотека · Analytica chimica acta · 2026

A blood-brain barrier-penetrating NIR fluorescent probe enables cross-model optical imaging of H2O2 in three neuroinflammation-related experimental mice models of brain injury.

Lu Yuxun, He Wenyi, Li Yinuo, Liu Yingping, Li Zhenhui, Zhang Ruqiu, Kong Fanyi, Li Fan, Zhou Ying

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Hydrogen peroxide (H2O2) is a key mediator of oxidative stress in neuroinflammation-related brain injury, yet brain H2O2 imaging remains challenging because of the blood-brain barrier (BBB) and tissue autofluorescence. In addition, most reported probes have been evaluated in only one or a few disease models, limiting cross-model comparison. Here, we developed MH-1, an H2O2-responsive near-infrared (NIR) fluorescent probe for brain-section optical mapping after systemic administration.

RESULTS

MH-1 exhibited an approximately 60-fold fluorescence turn-on at 667 nm, enabled H2O2 detection over 0.107-1000 μmol/L, and reached a stable response within approximately 30 min, with high selectivity, interference resistance, pH stability, and low cytotoxicity. Its fluorescence quantum yield increased from 0.72% to 2.45% upon activation. CD31 co-staining confirmed MH-1-associated fluorescence in extravascular brain parenchyma after systemic administration. Ex vivo brain-section imaging further revealed model-dependent H2O2-associated fluorescence in LPS-induced neonatal neuroinflammation, hypoxic-ischemic encephalopathy (HIE), and Alzheimer's disease (AD), with an effective imaging window of approximately 12 h.

SIGNIFICANCE: Rather than relying on a single best-in-class analytical parameter, MH-1 integrates NIR emission, a large fluorescence turn-on, BBB access, and applicability across three mechanistically distinct brain-injury models. This combined performance enables region-resolved, cross-model comparison of H2O2-associated oxidative stress in preclinical brain tissue.

Для цитирования: Lu Yuxun, He Wenyi, Li Yinuo, Liu Yingping, Li Zhenhui, Zhang Ruqiu, Kong Fanyi, Li Fan, Zhou Ying. A blood-brain barrier-penetrating NIR fluorescent probe enables cross-model optical imaging of H2O2 in three neuroinflammation-related experimental mice models of brain injury.. Analytica chimica acta. 2026. DOI: 10.1016/j.aca.2026.346241.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.