Interpretation of PlanIQ-derived feasibility dose-volume histogram f-values in lung SBRT with heterogeneous dose distributions.

Kamada Mayuka, Sasaki Motoharu, Nakaguchi Yuji, Kamomae Takeshi, Kanazawa Yuki, Yamaji Yuto, Sakuragawa Kanako, Tsuzuki Akira, Kasai Ryosuke, Ikushima Hitoshi

СтатьяПеревод пока не подготовлен

Аннотация

Feasibility dose-volume histogram (FDVH) analysis estimates patient-specific organ-at-risk dose-reduction feasibility, but the interpretation of FDVH-derived f-values in lung stereotactic body radiotherapy (SBRT) with heterogeneous target dosing remains unclear. This study evaluated FDVH-derived f-values in 25 peripheral lung cancer cases planned with VMAT-based SBRT. Plans were prescribed to 50 Gy in 4 fractions and normalized so that planning target volume (PTV) D95% corresponded to the prescription dose, while allowing target heterogeneity with PTV D2% of approximately 135% to 145% of the prescription dose. FDVH analysis was performed using PlanIQ under 2 conditions: Condition A used the clinical prescription dose, and Condition B used adjusted target reference doses derived from the mean minimum doses to the gross tumor volume (GTV) and PTV excluding the GTV (PTV-GTV). FDVH-derived f-values were evaluated for the ipsilateral normal lung and optimization Ring ROIs, and cases classified as the Impossible region (f = 0) were analyzed separately. For the ipsilateral normal lung, 6, 17, and 9 cases were classified as the Impossible region under Condition A for V10 Gy, V20 Gy, and mean lung dose, respectively; the corresponding numbers under Condition B were 5, 14, and 9. For the Ring ROIs, f-values were obtained for all cases under Condition B, with the highest median f-value observed for Ring 2 under both conditions. These findings suggest that FDVH estimates may not fully correspond to clinical dose distributions in lung SBRT with heterogeneous target dosing. FDVH-derived f-values should be interpreted with consideration of target dose heterogeneity and dose fall-off.

Для цитирования: Kamada Mayuka, Sasaki Motoharu, Nakaguchi Yuji, Kamomae Takeshi, Kanazawa Yuki, Yamaji Yuto, Sakuragawa Kanako, Tsuzuki Akira, Kasai Ryosuke, Ikushima Hitoshi. Interpretation of PlanIQ-derived feasibility dose-volume histogram f-values in lung SBRT with heterogeneous dose distributions.. Medical dosimetry : official journal of the American Association of Medical Dosimetrists. 2026. DOI: 10.1016/j.meddos.2026.09.001.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.