MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12882-026-05224-1

Медицинская библиотека · BMC nephrology · 2026

ApoB/ApoA-I ratio and all-cause mortality in maintenance hemodialysis: a cohort study.

Zhang Zhen, Xiang Fangfang, Jiang Wuhua, Cao Xuesen, Ding Xiaoqiang, Shen Bo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Traditional lipid markers have limited and inconsistent prognostic value in maintenance hemodialysis (MHD), a phenomenon often described as the lipid paradox. We evaluated whether lipid and apolipoprotein-related markers, particularly the ApoB/ApoA-I ratio, were associated with mortality in MHD patients.

METHODS

This single-center retrospective cohort study included 409 MHD patients. Lipid and apolipoprotein-related markers were analyzed as standardized continuous variables. Cox regression was used for all-cause mortality, and cause-specific Cox and Fine-Gray models were used for cardiovascular mortality.

RESULTS

During a median follow-up of 55.7 months, 148 all-cause deaths occurred, including 61 cardiovascular deaths. ApoB/ApoA-I was not associated with all-cause mortality in the unadjusted model, but was independently associated with all-cause mortality in Model 3 (hazard ratio [HR] 1.23, 95% confidence interval [CI] 1.05-1.44; p = 0.012). The association was similar in sensitivity analyses. ApoB/ApoA-I was not significantly associated with cardiovascular mortality in exploratory Fine-Gray regression (subdistribution hazard ratio [SHR] 1.12, 95% CI 0.89-1.43; p = 0.337) and did not improve discrimination beyond the base clinical model.

CONCLUSIONS

These findings suggest that ApoB/ApoA-I may contribute to risk characterization and etiologic understanding in MHD, but do not support its use as a stand-alone clinical prediction marker.

Для цитирования: Zhang Zhen, Xiang Fangfang, Jiang Wuhua, Cao Xuesen, Ding Xiaoqiang, Shen Bo. ApoB/ApoA-I ratio and all-cause mortality in maintenance hemodialysis: a cohort study.. BMC nephrology. 2026. DOI: 10.1186/s12882-026-05224-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.