MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d6ay01621a

Медицинская библиотека · Analytical methods : advancing methods and applications · 2026

The electrochemiluminescence immunosensor based on the Ce(III,IV)-MOF dual-function platform is used for the ultra-sensitive detection of AFP.

Liu Li, Ren Haoyi, Ji Tiantian, Li Shushu, Xue Hongyu, Hong Chenglin, Li Hongling

СтатьяПеревод пока не подготовлен

Аннотация

To address the challenges of unstable immobilization of tris(2,2'-bipyridine) ruthenium(II) (Ru(bpy)32+) and inefficient generation of the tri-n-propylamine radical (TPrA˙) in the Ru(bpy)32+/TPrA electrochemiluminescence (ECL) system, a novel dual-function strategy using a mixed-valence cerium metal-organic framework (Ce(III,IV)-MOF) was introduced in this study. The Ce(III,IV)-MOF was employed both as a scaffold for Ru(bpy)32+ and as a co-reaction catalyst. The three-dimensional structure of the Ce(III,IV)-MOF provides a stable environment for Ru(bpy)32+, while the Ce(III)/Ce(IV) redox pair within the framework facilitates TPrA oxidation through reversible single-electron transfer, thereby enhancing TPrA˙ generation. This design co-localizes the luminophore and catalytic centers within a single framework, reducing shortening the electron-transfer distance between Ru(bpy)32+ and the TPrA˙ site, and consequently enhancing the ECL performance of the Ru(bpy)32+/TPrA system. Compared with single-valence MOFs and their physically mixed MOF composites, the ECL performance of the Ru@Ce (III,IV)-MOF/TPrA system is significantly improved, with the maximum ECL signal amplification factor reaching up to 2.7 times. The sensor developed using this strategy showed a broad linear range (1 × 10-4 ng mL-1-100 ng mL-1) and a low detection limit (0.036 pg mL-1), together with excellent selectivity, stability, and reproducibility. This strategy provides a promising route for constructing multifunctional MOF-based ECL sensors for sensitive tumor biomarker detection.

Для цитирования: Liu Li, Ren Haoyi, Ji Tiantian, Li Shushu, Xue Hongyu, Hong Chenglin, Li Hongling. The electrochemiluminescence immunosensor based on the Ce(III,IV)-MOF dual-function platform is used for the ultra-sensitive detection of AFP.. Analytical methods : advancing methods and applications. 2026. DOI: 10.1039/d6ay01621a.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.