MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fcvm.2026.1880750

Медицинская библиотека · Frontiers in cardiovascular medicine · 2026

Extent of posterior wall lesion following pulmonary vein isolation with pentaspline pulsed field and cryoballoon ablation: the potential role of deployment technique.

Cobarro Lucía, Gómez-Burgueño Lorena, Negreira-Caamaño Martín, López-Alacid Isabel, Ramos-Jiménez Javier, Rajjoub Ez Alddin, Marco-DelCastillo Álvaro, Borrego-Bernabé Luis, Delgado Juan, Salguero-Bodes Rafael, Arribas-Ynsaurriaga Fernando, Rodríguez-Muñoz Daniel

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary vein isolation (PVI) using cryoballoon (CB) or pulsed field ablation (PFA) with a pentaspline catheter achieves similar efficacy in atrial fibrillation (AF), but lesion extension on the left atrial posterior wall (LAPW) may differ. Pentaspline-PFA (P-PFA) has been reported to create broader LAPW lesions, potentially leaving narrow viable corridors that have been hypothesized to be proarrhythmic.

OBJECTIVE

To descriptively compare the extent of chronic unintended left atrial posterior wall isolation after PVI with P-PFA and CB ablation.

METHODS

We conducted a single-center ambispective study including consecutive patients undergoing repeat left atrial mapping after index PVI with either P-PFA, using a protocol designed to ensure catheter alignment with the pulmonary veins, or CB. Patients with additional LA ablation between index procedure and remapping, unrelated LAPW scarring, or posterior pulmonary vein gaps were excluded. The primary endpoint was isolated LAPW area. Secondary endpoints included percentage of isolated LAPW and minimum residual corridor width.

RESULTS

Seventy-four patients were included in the analysis: 49 P-PFA and 25 CB. Mean age was 64.2 ± 10.0 years, 64.9% were male, and 55.4% had persistent AF. Isolated LAPW area was 8.3 ± 4.0 cm2 in the P-PFA group and 9.5 ± 3.9 cm2 in the CB group, with no statistically significant difference detected between groups (mean difference -1.26 cm2, 95% CI: -3.22 to 0.70; p = 0.203). The percentage of isolated LAPW area was 39.9 ± 17.6% vs. 38.9 ± 14.9% (p = 0.805), and minimum residual corridor width was 19.7 ± 9.9 vs. 18.6 ± 11.0 mm (p = 0.671), respectively. P-PFA was associated with shorter procedure time (44.2 ± 10.2 vs. 65.8 ± 24.6 min; p < 0.001), shorter LA dwell time (38.1 ± 9.6 vs. 60.6 ± 20.5 min; p < 0.001), lower fluoroscopy time (5.3 ± 3.9 vs. 13.0 ± 9.7 min; p < 0.001), and lower dose-area product [5.3 (2.8-9.7) vs. 19.3 (6.5-31.0) Gy·cm2; p < 0.001].

CONCLUSION

In this descriptive, hypothesis-generating study, no statistically significant difference in chronic LAPW isolation extent was detected between P-PFA and CB ablation. These findings support the hypothesis that catheter deployment technique may influence posterior wall lesion geometry, warranting confirmation in adequately powered prospective studies.

Для цитирования: Cobarro Lucía, Gómez-Burgueño Lorena, Negreira-Caamaño Martín, López-Alacid Isabel, Ramos-Jiménez Javier, Rajjoub Ez Alddin, Marco-DelCastillo Álvaro, Borrego-Bernabé Luis, Delgado Juan, Salguero-Bodes Rafael, Arribas-Ynsaurriaga Fernando, Rodríguez-Muñoz Daniel. Extent of posterior wall lesion following pulmonary vein isolation with pentaspline pulsed field and cryoballoon ablation: the potential role of deployment technique.. Frontiers in cardiovascular medicine. 2026. DOI: 10.3389/fcvm.2026.1880750.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.