MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12471-026-02082-2

Медицинская библиотека · Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2026

Development of an artificial intelligence algorithm for automated detection of cardiovascular intervention-related complications.

Okken Arnoud, Wanders Rob, Klappe Andre, Beukema Kasper F, Oirbans Tom, Noordzij Peter G, van Lent Anouk, Haanemaaier Saskia H, Balt Jippe C

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Intervention-related complications negatively affect healthcare quality and costs. Complication registration and reporting play an important role in the improvement of healthcare outcomes but are time-consuming and hampered by under-reporting.

METHODS

We developed an artificial intelligence (AI)-aided tool that extracts specific complications, including bleeding, tamponade, CVA and phrenic paralysis, from electronic healthcare records of patients undergoing pulmonary vein isolation (PVI), percutaneous transluminal coronary angioplasty (PTCA) and transcatheter aortic valve implantation (TAVI). Both structured and unstructured data were used, along with additional signals identified through machine learning. The model was optimized to achieve high sensitivity.

RESULTS

Electronic records of 6,564 patients undergoing PVI, PTCA, and TAVI, performed at our hospital from 2017-2022, were used. The final model detected the various complications with a sensitivity between 94.4 and 100%, while specificity ranged from 99.4-100%. This resulted in positive predictive values ranging from 47.5-81%, with F‑scores varying between 0.64-0.87.

CONCLUSION

We developed an AI-driven tool capable of automatically detecting complications following cardiac interventions from patient healthcare records, achieving a very high sensitivity. Our tool enables registration of complications while significantly reducing administrative burden on the healthcare providers and data managers. It provides valuable and high-quality input for improvement cycles, thereby enhancing patient safety and healthcare quality.

Для цитирования: Okken Arnoud, Wanders Rob, Klappe Andre, Beukema Kasper F, Oirbans Tom, Noordzij Peter G, van Lent Anouk, Haanemaaier Saskia H, Balt Jippe C. Development of an artificial intelligence algorithm for automated detection of cardiovascular intervention-related complications.. Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation. 2026. DOI: 10.1007/s12471-026-02082-2.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.