MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.jafc.6c08928

Медицинская библиотека · Journal of agricultural and food chemistry · 2026

LC-MS/MS Quantification of Total Milk Protein Allergens: A Dual-Target Approach Using β-Lactoglobulin/β-Casein Standards and Stable Isotope-Labeled Peptide Calibration.

Yang Shupeng, Xu Yutong, Chen Ruijie, Siyi Li, Shencheng Yingnan, Jia Xiaoxue, Liu Shuyan, Gao Yanan, Gao Min, Li Yi

СтатьяОценочное исследованиеПеревод пока не подготовлен

Аннотация

Accurate quantification of total milk protein allergens in foods remains challenging due to processing-induced alterations in whey-to-casein ratios and matrix interference effects. Herein, a LC-MS/MS method was developed and validated for accurate quantification of milk allergens in foods using a novel dual-target approach. This method simultaneously quantifies whey and casein fractions using high-purity protein standards of β-lactoglobulin and β-casein through marker peptides LIVTQTMK and VLPVPQK, respectively, coupled with stable isotope-labeled peptide internal standards containing flanking sequences. The dual-target strategy overcomes limitations of conventional single-target methods by providing accurate total milk protein determination regardless of processing-induced alterations in protein ratios. Method validation demonstrated excellent performance with detection limits of 0.1 mg/kg for β-lactoglobulin and β-casein, recovery rates of 80.6%-92.4%, and precision below 12.7% RSD. This dual-target approach provides a robust analytical tool for accurate milk allergens determination in processed foods, significantly advancing allergen control and regulatory compliance.

Для цитирования: Yang Shupeng, Xu Yutong, Chen Ruijie, Siyi Li, Shencheng Yingnan, Jia Xiaoxue, Liu Shuyan, Gao Yanan, Gao Min, Li Yi. LC-MS/MS Quantification of Total Milk Protein Allergens: A Dual-Target Approach Using β-Lactoglobulin/β-Casein Standards and Stable Isotope-Labeled Peptide Calibration.. Journal of agricultural and food chemistry. 2026. DOI: 10.1021/acs.jafc.6c08928.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.