MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.joca.2026.10.010

Медицинская библиотека · Osteoarthritis and cartilage · 2026

Optical monitoring of inflammatory response in joint explant cultures using near infrared spectroscopy.

Sadeesh Nithin, Safari Fatemeh, Jalali Abolfazl, Zvicer Jovana, Gebraad Arjen, Nippolainen Ervin, Miettinen Susanna, Grad Sibylle, Li Zhen, Afara Isaac O

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate near-infrared (NIR) spectroscopy combined with machine learning (ML) for detecting and estimating inflammatory and matrix-related biomarkers released into the culture medium of an explant model.

MATERIALS AND

METHODS

Bovine osteochondral explants and synovial tissues were co-cultured under inflammatory factor-treated (IF-treated) conditions that mimic osteoarthritis (OA) and non-IF-treated conditions. The co-cultures were maintained for seven days with the culture medium collected and replaced daily. The samples were subjected to NIR spectral measurements (900-1700 nm), followed by measurement of sulphated glycosaminoglycans (sGAG), nitric oxide (NO), interleukin (IL)-6, and IL-8 released into the culture. Acquired spectra were preprocessed and analyzed for classification and estimation of biomarkers using ML-based models. Feature importance analyses were performed to identify key wavelength features that contribute to classification and prediction of biomarkers.

RESULTS

Biomarker release showed a substantial increase in the OA-like setup compared to the non-IF-treated setup. During classification, the IF-treated and non-IF-treated spectra showed distinct patterns, with noticeable differences in the 1440-1520 nm and 1600-1700 nm regions. Using these spectral variations, the best performing classifier achieved an accuracy of 95.3% in distinguishing OA-like from non-IF-treated samples. The regression analysis also showed good regression performance with R² values of 0.44 (sGAG), 0.48 (NO), 0.42 (IL-6), and 0.36 (IL-8).

CONCLUSIONS

This study showed that NIR spectroscopy combined with ML can detect and quantify OA-related spectral signatures in explant media, thereby demonstrating its potential as a non-destructive and rapid method for monitoring inflammatory activity in ex vivo OA models.

Для цитирования: Sadeesh Nithin, Safari Fatemeh, Jalali Abolfazl, Zvicer Jovana, Gebraad Arjen, Nippolainen Ervin, Miettinen Susanna, Grad Sibylle, Li Zhen, Afara Isaac O. Optical monitoring of inflammatory response in joint explant cultures using near infrared spectroscopy.. Osteoarthritis and cartilage. 2026. DOI: 10.1016/j.joca.2026.10.010.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.