MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.6c05086

Медицинская библиотека · Analytical chemistry · 2026

Electrokinetic Enrichment and Purification of Proteins and Anions from High-salt Samples on Liquid Plasticine-Based Open Chip.

Niu Jicheng, Fu Wenxuan, Su Bin, Wang Zhen

СтатьяПеревод пока не подготовлен

Аннотация

Microfluidic chips are promising for on-site analysis in medical diagnostics and food safety because they enable miniaturized, integrated sample processing. However, the analysis of complex, salt-rich matrices of biological and food samples remain challenging for conventional closed chips and electrokinetic pretreatment methods. Here, we developed an open, reconfigurable electrophoresis chip based on liquid plasticine, in which a moving neutralization reaction electrophoresis system (MNRES) was implemented for high-salt sample pretreatment. Liquid plasticine enabled facile construction of pump-free, valve-free, optically transparent, and cuttable open reservoirs and channels. In the MNRES, OH- and H+ generated by water electrolysis reacted with NH4+ and CH3COO-, producing moving neutralization reaction boundaries accompanied by dynamic electric field and pH gradients. These two coupled gradients enabled salt removal, field amplified stacking, and meanwhile the pH gradient induced protein focusing, thereby allowing simultaneous enrichment and purification of proteins and anionic species. It is demonstrated that proteins and anionic species in 0.9% NaCl solution can be effectively separated and enriched by approximately 10-fold. Moreover, the MNRES-pretreated analyte zones can be directly monitored by smartphone-based online colorimetry or transferred to liquid-plasticine microreactors for offline chromogenic assays. This work provides a flexible open-fluidic strategy for integrated electrokinetic pretreatment and visual detection of complex high-salt samples.

Для цитирования: Niu Jicheng, Fu Wenxuan, Su Bin, Wang Zhen. Electrokinetic Enrichment and Purification of Proteins and Anions from High-salt Samples on Liquid Plasticine-Based Open Chip.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.6c05086.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.