Sorption-spectrophotometric determination of Ni(II) in natural waters using nitrazine yellow immobilised on a polyamine-modified polyacrylonitrile fibre.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Madatov Utkirjon, Rakhimov Samariddin, Smanova Zulayxo, Tursunqulov Jasur, Tojiboyeva Feruzakhon, Turaeva Xonzoda, Shakhidova Dilbar, Rajabov Khudayor, Jumaniyazova Mukaddas, Eshchanova Aziza, Matmurodova Feruza, Djumaniyazov Zokir, Kutlimurotova Rukhiya, Khasanov Shakhboz
Аннотация
A solid-phase sorption-spectrophotometric procedure was developed for the determination of Ni(II) in natural waters using nitrazine yellow (NY) immobilised on PPA-1, an anion-exchange fibre obtained by treating hydroxylamine-activated polyacrylonitrile with polyethylene polyamine. Reagent immobilisation and Ni(II) binding were characterised by absorption and diffuse-reflectance spectroscopy, Raman spectroscopy, conductometry and scanning electron microscopy with energy-dispersive X-ray analysis (SEM-EDS). In aqueous solution, the absorption maximum of NY shifts from 465 to 583 nm on complexation with Ni(II) (Δλ = 118 nm), whereas on the fibre the Kubelka-Munk maximum shifts from 470 to 620 nm (Δλ = 150 nm), so that the analytical signal is measured where the reagent-loaded blank absorbs only weakly. For the solid-phase determination (50 mL sample, pH 6.4, 0.2000 g of NY-loaded fibre, 10 min contact time, no free reagent added), ΔF(R) at 620 nm was linear in the mass of Ni(II) over 4.2-88.5 µg per 50 mL (84-1770 µg L-1; R2 = 0.9985, ten levels, four replicates each). The limits of detection and quantification (3sy/x/b and 10sy/x/b) were 72 and 240 µg L-1, and the repeatability was 0.1-0.9% (RSD, n = 4). The solution reaction, used only for spectral characterisation, has a molar absorptivity of 3.8 × 104 L mol-1 cm-1 at 583 nm and a Sandell sensitivity of 0.0016 µg cm-2. Cu(II), Fe(II), Fe(III), Zn(II), Mn(II), Co(II), Pb(II) and Hg(II) were tolerated at a tenfold mass excess over Ni(II) (recoveries 99.3-100.0%). Ni(II) added to Zarafshan River water at 400-1000 µg L-1 was recovered at 97.5-104.0% (RSD 4.2-7.3%, n = 5) without significant bias. Because the LOQ exceeds the WHO drinking-water guideline value (70 µg L-1), the procedure in its present form is suited to Ni(II)-contaminated surface waters and wastewaters; monitoring at the guideline level would require prior preconcentration. The procedure is solvent-free and uses an inexpensive, disposable fibrous sensing phase that is easily separated from the sample.