Feasibility of longitudinal prostate R2 ⁎ measurements in patients undergoing stereotactic ablative radiotherapy on an MRI-linac.

Moore Chris, Ezekiel Asher, Bamunuarachchi Vodathi, Saad Ereny, Datta Anubhav, Hoskin Peter, Choudhury Ananya, van Herk Marcel, Buckley David L, Dubec Michael J, McHugh Damien J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Tissue R2* (1/T2*), sensitive to deoxyhaemoglobin, is a proposed hypoxia biomarker in prostate cancer. This exploratory work investigates prostate R2* and volume throughout and after hypo-fractionated radiotherapy and the effects of androgen deprivation therapy (ADT).

MATERIALS AND

METHODS

Fifteen patients (seven with ADT) received five-fraction stereotactic-ablative-radiotherapy (SABR) on a 1.5 T Elekta Unity MRI-linac, with R2* mapping at MR-Simulation and treatment visits 1, 3, 5. Six patients had follow-up imaging post-treatment.Treatment-induced whole-prostate and tumour R2*/volume differences were investigated using repeated-measures analysis-of-variance.ADT effects on baseline whole-prostate R2*/volume were investigated using unpaired t-tests. Spearman correlations between whole-prostate R2* and volume were calculated before and during treatment.

RESULTS

Whole-prostate R2* (mean difference [95% CIs] = -1.77 [-2.17 to -0.498] s-1, p = 0.003) and tumour R2* (-3.11 [-5.78 to -1.44] s-1, p = 0.003) decreased, whole-prostate volume (8.05 [4.76 to 11.7] cm3) increased after two fractions.Follow-up whole-prostate R2* (p = 0.62) and volume (p = 0.16) were not significantly different from baseline.ADT patients had higher baseline whole-prostate R2* (p = 0.006) and lower volume (p = 0.003). ADT did not impact treatment-induced changes (p = 0.51).Baseline whole-prostate R2*/volume were negatively correlated (r = -0.75, p = 0.002); treatment-induced R2*/volume changes were not correlated r = 0.44, p = 0.11).

CONCLUSIONS

Treatment-induced whole-prostate and tumour R2* changes were measured after two SABR fractions. Post-treatment whole-prostate R2* and volume were not significantly different from baseline.Further work is required to confirm the mechanism(s) causing observed treatment effects.

Для цитирования: Moore Chris, Ezekiel Asher, Bamunuarachchi Vodathi, Saad Ereny, Datta Anubhav, Hoskin Peter, Choudhury Ananya, van Herk Marcel, Buckley David L, Dubec Michael J, McHugh Damien J. Feasibility of longitudinal prostate R2 ⁎ measurements in patients undergoing stereotactic ablative radiotherapy on an MRI-linac.. Physics and imaging in radiation oncology. 2026. DOI: 10.1016/j.phro.2026.101103.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.