MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.116666

Медицинская библиотека · Cureus · 2026

Sex-Based Differences in Gastroduodenal Artery Morphometry.

Stewart Morgan W, Watts Jenna M, Schmidt Vincent J, Aulakh Simran, Smith Cameron T, Dunivin Forrest, Kirkland Julia, Zolnierz Melissa

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The gastroduodenal artery (GDA) supplies the upper gastrointestinal tract, and variation in its geometry may influence endovascular access and hepatobiliary interventions. This study evaluated sex-based differences in the GDA branching angle and diameter using standardized morphometric analysis.

METHODS

This retrospective cadaveric morphometric study included 28 formalin-embalmed donors (12 males and 16 females) examined between 2024 and 2025. Inclusion criteria required an intact GDA and common hepatic artery suitable for analysis. Following targeted vessel dissection, perpendicular images were obtained with in-plane calibration and analyzed using ImageJ (National Institutes of Health, Bethesda, MD, USA). Branching angle and mid-segment diameter were measured independently by two blinded observers. Sex-based differences were assessed using independent-samples t-tests, applying Welch's correction when the assumption of homogeneity of variance was violated.

RESULTS

Twenty-eight donors (mean age 77 ± 8 years; 12 males and 16 females) were evaluated. Male donors demonstrated significantly smaller GDA branching angles than female donors (95.83° ± 23.79° vs. 119.51° ± 17.75°; p = 0.006) and significantly larger diameters (5.67 ± 2.57 mm vs. 3.17 ± 0.70 mm; p = 0.007).

CONCLUSION

Sex-based differences were identified in GDA geometry, which may influence computed tomography (CT) angiography interpretation and interventional planning.

Для цитирования: Stewart Morgan W, Watts Jenna M, Schmidt Vincent J, Aulakh Simran, Smith Cameron T, Dunivin Forrest, Kirkland Julia, Zolnierz Melissa. Sex-Based Differences in Gastroduodenal Artery Morphometry.. Cureus. 2026. DOI: 10.7759/cureus.116666.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.