Heel-Rise Test for functional assessment in chronic venous insufficiency: a validity study.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Reis Marina Silva, Silva Keity Lamary Souza, Pereira Antonielly Rocha de Souza, Chaves Vivian Camargo, Nery Stefânia Guimarães, Silva Dalyla Lemos de Souza, Figueiredo Pedro Henrique Scheidt, Costa Henrique Silveira
Аннотация
BACKGROUND: Chronic venous insufficiency (CVI) affects the superficial and/or deep venous system and is often associated with valve abnormalities and calf pump dysfunction, including reduced lower limb strength. Assessment of calf muscle strength should be part of the clinical routine for these patients. The Heel-Rise Test (HRT) has been proposed for this purpose, but its correlation with other functional instruments remains unclear.
OBJECTIVES: To verify the validity of the HRT for assessment of calf muscle strength and endurance in patients with CVI by comparing it with other functional tests.
METHODS: Fifty-two patients with CVI (mean age of 67.2±13.2 years, CEAP 1 to 6) were evaluated. All patients undertook the HRT and were instructed to perform maximal plantar flexions until exhaustion. The number of repetitions and the time taken to complete the test were recorded. All Sit-to-Stand test variants (STS5, STS10, STS30, STS60) were also administered. Handgrip dynamometry, the Human Activity Profile (HAP), and the CIVIQ-14 questionnaire were also administered. Correlations were analyzed using Pearson or Spearman tests.
RESULTS: HRT repetitions correlated significantly with STS5 (r = -0.676), STS10 (r = -0.701), STS30 (r = 0.691), STS60 (r = 0.697), handgrip dynamometry (r = 0.275), HAP (r = 0.457), and CIVIQ-14 (r = -0.646). However, HRT execution time was not correlated with handgrip dynamometry or CIVIQ-14.
CONCLUSIONS: The HRT is related to calf muscle strength, endurance, and functionality in patients with CVI and should be used for functional assessment of these patients.
OBJECTIVES: To verify the validity of the HRT for assessment of calf muscle strength and endurance in patients with CVI by comparing it with other functional tests.
METHODS: Fifty-two patients with CVI (mean age of 67.2±13.2 years, CEAP 1 to 6) were evaluated. All patients undertook the HRT and were instructed to perform maximal plantar flexions until exhaustion. The number of repetitions and the time taken to complete the test were recorded. All Sit-to-Stand test variants (STS5, STS10, STS30, STS60) were also administered. Handgrip dynamometry, the Human Activity Profile (HAP), and the CIVIQ-14 questionnaire were also administered. Correlations were analyzed using Pearson or Spearman tests.
RESULTS: HRT repetitions correlated significantly with STS5 (r = -0.676), STS10 (r = -0.701), STS30 (r = 0.691), STS60 (r = 0.697), handgrip dynamometry (r = 0.275), HAP (r = 0.457), and CIVIQ-14 (r = -0.646). However, HRT execution time was not correlated with handgrip dynamometry or CIVIQ-14.
CONCLUSIONS: The HRT is related to calf muscle strength, endurance, and functionality in patients with CVI and should be used for functional assessment of these patients.