Pulmonary Vein Isolation With Contact-Force-Sensing Large-Tip Focal Pulsed Field Ablation Catheter With 3D Mapping for Paroxysmal Atrial Fibrillation: Omny-IRE 12-month Results.

Duytschaever Mattias, Vijgen Johan, Neuzil Petr, Grimaldi Massimo, Verma Atul, De Potter Tom, Macle Laurent, Kautzner Josef, Linz Dominik, Anic Ante, Chun Julian, Van Herendael Hugo, Almorad Alexandre, Berte Benjamin, Bhardwaj Rahul, Reichlin Tobias, Mansour Moussa, Schmidt Boris, Knecht Sebastien, Reddy Vivek Y, Rackauskas Gediminas

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Omny-IRE (NCT05971693) evaluated safety and effectiveness of a large-tip focal, multielectrode, contact-force-sensing, pulsed field ablation, basket catheter with electroanatomic mapping integration.

OBJECTIVE

Report 12-month (M) study outcomes.

METHODS

Pulmonary vein isolation was performed using the OMNYPULSE platform. Patients underwent follow-up through 12M postablation visit with electrocardiography (preprocedure, predischarge, and at 1, 3, 6, and 12M), 24-hour Holter monitoring (3, 6, and 12M), and remote rhythm monitoring (weekly: 1-5M; monthly: 6-12M; and symptom-triggered recordings). The secondary effectiveness endpoint was 12M freedom from documented symptomatic/asymptomatic atrial arrhythmia (≥30 s) and acute procedural failure. Device/procedure-related serious adverse events (SAEs), quality-of-life assessed by Atrial Fibrillation Effect on Quality-of-Life (AFEQT) scores, and healthcare-utilization (cardiovascular-hospitalizations and antiarrhythmic drug [AAD] use) were also evaluated.

RESULTS

Among 188 enrolled patients, 136 comprised the main-phase-cohort for safety and effectiveness evaluations. In this cohort, 12M freedom from symptomatic/asymptomatic atrial arrhythmia was 82.5% (90.1% using standard-of-care monitoring only). Clinical success, defined as freedom from documented symptomatic arrhythmia and acute procedural failure, was 89.9%, while single procedural success was 89.2%. Device/procedure-related SAEs occurred in 2.9% of main-phase patients. Mean overall AFEQT score improved by 25.5 points from baseline to 12M. Cardiovascular-hospitalizations decreased by 40.9% versus the 12M preprocedure period, and Class I/III AAD use decreased by 49.3% 6-12M postablation versus baseline.

CONCLUSIONS

Omny-IRE results demonstrated the effectiveness, safety, and healthcare benefits of PFA with the OMNYPULSE platform.

Для цитирования: Duytschaever Mattias, Vijgen Johan, Neuzil Petr, Grimaldi Massimo, Verma Atul, De Potter Tom, Macle Laurent, Kautzner Josef, Linz Dominik, Anic Ante, Chun Julian, Van Herendael Hugo, Almorad Alexandre, Berte Benjamin, Bhardwaj Rahul, Reichlin Tobias, Mansour Moussa, Schmidt Boris, Knecht Sebastien, Reddy Vivek Y, Rackauskas Gediminas. Pulmonary Vein Isolation With Contact-Force-Sensing Large-Tip Focal Pulsed Field Ablation Catheter With 3D Mapping for Paroxysmal Atrial Fibrillation: Omny-IRE 12-month Results.. Heart rhythm. 2026. DOI: 10.1016/j.hrthm.2026.10.008.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.